Pr.1019 = "0" (output without minus sign)
Analog output
Limited at 10 V
Current (AM1): 20 mA
Voltage (AM0): 10 V
-100%
0
Analog output value
(Pr.307 or Pr.311)
for zero output signal
NOTE
• When Pr.307 = Pr.308 and Pr.311 = Pr.312, the output values from terminals AM0 and AM1 will always be the values that
are set in the parameters.
30
ANALOG OUTPUT
Limited at 10 V
Output signal
100%
value
Analog output value
(Pr.308 or Pr.312) for
maximum output signal
Pr.309 = "10, 11"
Pr.1019 = "1" (output with minus sign)
Current (AM1): 20 mA
Voltage (AM0): 10 V
Analog output value
(Pr.307 or Pr.311)
for zero output signal
-100%
Limited at -10 V
Analog output
0
100%
Analog output value
(Pr.308 or Pr.312) for
maximum output signal
-10V
Limited at 10 V
Output signal
value