Bindicator Mark-4 Installation & Operation Manual page 25

Table of Contents

Advertisement

STATUS MESSAGE
SENSOR IS NORMAL
STARTING MEASURE
SENSOR IS MEASURING
PERFORMING TEST
INHIBITED TO MEASURE
MAXMOVE DIST REACHED
UP/DOWN DO NOT MATCH
LOST WEIGHT
STUCK WEIGHT
INVALID REPLY
4-20 mA CONFIG ERROR
INVALID ERROR CODE
OVRFLOW
UNIT ERROR
%ERROR
ERROR IN MAT/AIR MOD
Please note that the first three items in this list are not errors, but sensor status reports only. The remaining
items are actual errors. For obvious reasons, some errors overlay other errors. For example, a sensor without
communications cannot report its status.
LBY180112 Rev. B
DESCRIPTION
Sensor is normal.
Sensor is starting measurement. A command has been sent to the sensor to start a
measurement and the sensor is ensuring that the weight is in the home posiiton.
Sensor is taking a measurement.
Sensor is performing a 4-20 mA test.
Sensor measurement is inhibited.
Sensor has reached the "max move distance" without contacting material in the tank.
"Up" counts and "Down" measurements do not agree.
Weight is missing or no weight is on the cable.
Weight is stuck.
Communication trouble or invalid reply.
Error in the configuration of the 4-20 mA output.
The error code received by the display is wrong.
If measurement is greater than 9,999,999 engineering units (or 100m if set in meters or
200 ft. if set in feet), this message will be shown instead of level, weight, or volume.
If the unit of measurement received by the display is wrong, this message will be
shown instead of level and units.
If the percentage received by the display is wrong, this message will be shown instead
of the percentage.
If the display mode received by the display is wrong, this message will be shown
instead of the display mode.
21
www.bindicator.com

Advertisement

Table of Contents
loading

Related Products for Bindicator Mark-4

This manual is also suitable for:

Gp-4Yo-yo

Table of Contents