IV. MECHANICAL INSTALLATION
WARNING: REMOVE POWER FROM THE UNIT bEFORE INSTALLING, REMOVING OR MAKING
ADjUSTMENTS.

GUIDELINES

- Should not be close to any fill point.
-
To ensure material does not get into the enclosure, it is recommended that the unit be placed where an
air purge is available.
-
Sensing weights should weigh between 20 - 25 oz (567 - 709 g)
-
The standard plastic weight and spike require additional weight to reach recommended weight; it is
recommended that the weight be filled with the same material that is in the vessel.
- For round, center fill, center discharging vessels, it is recommended that mounting should be located at
a point approximately
-
For other types of vessel shapes, contact Customer Support for assistance in determining ideal
mounting locations.

GENERAL INSTALLATION

1. Determine location of where sensor should be on the top of the tank.
2. Insert unit into the tank with weight going into the vessel.
3. Mount the unit to the top of the vessel using a 3" NPT nozzle or pipe nipple extended vertically from the
top.
NOTE: Due to how the weight is retracted, for the Digestible Bottle Weight a 12 in. (30.5 cm) nozzle is
recommended; for the Stainless Steel Bob Weight a 3 in. (7.62 cm) nozzle is recommended. Other weights do
not need additional considerations.
4. Secure the unit to the mounting/flange.
5. Proceed to Electrical Section for wiring instructions.

REMOTE DISPLAY UNIT INSTALLATION

1. Determine location of display – should be mounted where it can be easily read by user.
2. Install feet on enclosure, tightening at the desired angles for mounting location.
3. Hold the enclosure against the wall in the desired location and mark the positions of the mounting holes.
Place the enclosure in a safe location.
4. Drill the mounting holes into the wall.
5. Attach the enclosure to the wall using hardware (provided by the customer) that will secure it firmly in
place.
6. Proceed to Electrical Section for wiring instructions.
/
of the vessel radius from the vessel wall.
1
3
6
www.bindicator.com