Intec 980951 Manual page 12

Table of Contents

Advertisement

Available languages

Available languages

STEP 4
Constant
voltage
STEP 5
Buffer
STEP 6
Pulsed current
cycle
ATTENTION: Because of the high voltage reached during this charging cycle, the battery
recovery process must be performed with the battery disconnected from the vehicle. Recovery
with the battery connected to the vehicle may result in damage to the vehicle's electronics.
Minimum battery voltage: If the initial voltage of the battery is lower than 3 V, the battery
cannot be recovered.
3.2 «
Flash
» supply and «
Preset supply current ranges:
«
Flash
»
10 A
Supply current set to 10 A
30 A
Supply current set to 30 A
60 A
Supply current set to 60 A
120 A
Supply current set to 120 A
3.3 «
Flash
» supply voltage and supported batteries «
Preset supply voltage ranges:
14.8 V
Supply voltage set to 14.8 V
14.4 V
Supply voltage set to 14.4 V
13.8 V
Supply voltage set to 13.8 V
3.4 Saving settings
The battery charger saves the settings on the front control panel. In the event of an accidental
power loss or voluntary power off, when the charger is restarted, it will restart with the latest
saved settings.
With the battery charger set to the «
when the power supply is restored.
Whereas in the «
Charge
«
Start/Stop
» button will have to be pressed, to resume the normal charge cycle.
3.5 Battery testing
The tests within the operating modes may terminate with the signaling of some errors.
Keeps the battery at charge end voltage.
Voltage drops to the maintenance level and the charging cycle is
completed. The green «
Pulsed battery maintenance cycle (over long periods).
Amperage
» charging mode
Preset charging bands to select connected battery
(output current adjusted automatically):
«
Charge
5 - 100 Ah
100 - 300 Ah
300 - 600 Ah
600 - 1200 Ah
Flash
» mode, the work cycle will resume automatically
» mode, the screen will display the error message "ER01", and the
- 12 -
Full
» LED turns on.
»
Supports batteries from 5 Ah to 100
Ah
Supports batteries from 100 Ah to
300 Ah
Supports batteries from 300 Ah to
600 Ah
Supports all batteries from a minimum
of 600 Ah to a maximum of 1200 Ah
Volt/Batt.
»
Preset battery types:
AGM
Flat plate AGM batteries or Optima
type spiral batteries. Charge end
at 14.7 V.
LiFePO4
LiFePO4 batteries. End of charge
at 14.5 V.
Wet
Acid electrolyte batteries. Charge
end at 14.4 V.
EN

Advertisement

Table of Contents
loading

Table of Contents