4
Technical data
4.1
Product properties
IP code
Weight
Nominal pressure
Permissible pressure
Water connection
Maximum inflow temperature
Maximum inflow pressure
Nominal flow rate (water)
Maximum flow rate (water)
Maximum suction head (only with hose fully filled)
Ambient temperature for operation
Storage temperature
4.2
Battery
Battery operating voltage
Weight, battery
Ambient temperature for operation
Storage temperature
Battery charging starting temperature
5

Preparations at the workplace

WARNING
Risk of injury by inadvertent starting!
▶ Before inserting the battery, make sure that the product is switched off.
▶ Remove the battery before making any adjustments to the power tool or before changing accessories.
Observe the safety instructions and warnings in this documentation and on the product.
5.1
Charging the battery
1. Before charging the battery, read the operating instructions for the charger.
2. Make sure that the contacts on the battery and the contacts on the charger are clean and dry.
3. Use an approved charger to charge the battery. → page 5
*2404923*
2404923
PC 2-22
IP X5 (Protection against water jets
from all directions)
2.1 kg
(4.63 lb)
40 bar ±3 bar
(580 psi ±44 psi)
6 MPa
(870 psi)
1⁄2" water hose / coupling
40 ℃
(104.0 ℉)
0.6 MPa
(87 psi)
2.2 ℓ/min
(0.58 liq. gal
/min)
US
4.5 ℓ/min
(1.19 liq. gal
/min)
US
4 m
(13 ft - 1 in)
0 ℃ ... 60 ℃
(32.0 ℉ ... 140.0 ℉)
−20 ℃ ... 70 ℃
(−4.0 ℉ ... 158.0 ℉)
21.6 V
See the end of these operating
instructions
−17 ℃ ... 60 ℃
(1.4 ℉ ... 140.0 ℉)
−20 ℃ ... 40 ℃
(−4.0 ℉ ... 104.0 ℉)
−10 ℃ ... 45 ℃
(14.0 ℉ ... 113.0 ℉)
English
7