en | General installation procedures
Ventilation (for all models)
The airflow direction is side-to-rear. In general, setting up or mounting the power amplifier
has to be done in a way that fresh air can enter unhindered at the side and exhausted air
can exit at the rear. When installing the power amp in a case or rack system, attention
should be paid to these details to provide sufficient ventilation.
Figure 4.9: Rack mounting of several SYNSONA amplifiers. Illustration of the PRM-4P600 model.
Caution!
Blocking/closing the power amp's ventilation louvers is not permissible. Without sufficient
!
cooling/ventilation, the power amplifier may enter protect mode.
Keep ventilation louvers free from dust to ensure unhindered airflow.
Notice!
i
Do not use the power amplifier in direct sunlight or near heat sources, like heater blowers,
stoves, or any other heat radiating devices.
2024.01 | V03 | F.01U.402.247
Allow for an air duct of at least 60 mm between the rear panel of the power amplifier
and the inner wall of the cabinet/rack case.
Make sure that the duct reaches up to the cabinets or the rack case's top ventilation
louvers.
Leave room of at least 100 mm above the cabinet/rack case for ventilation. Since
temperatures inside of the cabinet/rack case can easily rise up to 40 °C during
operation of the power amp, it is mandatory to bear in mind the maximum allowable
ambient temperature for all other appliances installed in the same cabinet/rack case.
Installation manual
SYNSONA amplifiers