Seneca S311D L Series User Manual

Seneca S311D L Series User Manual

Advanced digital indicators-totalizers
Hide thumbs Also See for S311D L Series:

Advertisement

Quick Links

USER MANUAL
S311D-XX-L/S311D-XX-H
ADVANCED DIGITAL INDICATORS-TOTALIZERS
4-, 6-, 8-, 11-DIGIT DISPLAY
SENECA S.r.l.
Via Austria 26 – 35127 – Z.I. - PADOVA (PD) - ITALY
Tel. +39.049.8705355 – 8705355 Fax +39 049.8706287
www.seneca.it
ORIGINAL INSTRUCTIONS

Advertisement

loading
Need help?

Need help?

Do you have a question about the S311D L Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Seneca S311D L Series

  • Page 1 USER MANUAL S311D-XX-L/S311D-XX-H ADVANCED DIGITAL INDICATORS-TOTALIZERS 4-, 6-, 8-, 11-DIGIT DISPLAY SENECA S.r.l. Via Austria 26 – 35127 – Z.I. - PADOVA (PD) - ITALY Tel. +39.049.8705355 – 8705355 Fax +39 049.8706287 www.seneca.it ORIGINAL INSTRUCTIONS...
  • Page 2 User Manual S311D-XX-L/S311-XX-H www.seneca.it ALL RIGHTS RESERVED. NO PART OF THIS PUBLICATION MAY Doc: MI-00550-0-EN Rev. 1 Page 2 BE REPRODUCED WITHOUT PRIOR PERMISSION.
  • Page 3: Contact Information

    (available if the optional board is used). CONTACT INFORMATION Technical Support supporto@seneca.it Product information commerciale@seneca.it This document is the property of SENECA srl. Copies and reproduction are prohibited unless authorised www.seneca.it ALL RIGHTS RESERVED. NO PART OF THIS PUBLICATION MAY Doc: MI-00550-0-EN Rev. 1 Page 3 BE REPRODUCED WITHOUT PRIOR PERMISSION.
  • Page 4: Modbus Commands Supported

    2 and bit 1, and serves to illustrate the meaning of the various united combinations of the values of the two bits. On the other hand, the symbol * indicates the default value. www.seneca.it ALL RIGHTS RESERVED. NO PART OF THIS PUBLICATION MAY Doc: MI-00550-0-EN Rev.
  • Page 5 Same maximum and minimum limits as HI_D_LONG (40004-5). DP_D/DP_IN/DP_TOT Decimal point position for frequency value of the HI-F 40008 7 R/W www.seneca.it ALL RIGHTS RESERVED. NO PART OF THIS PUBLICATION MAY Doc: MI-00550-0-EN Rev. 1 Page 5 BE REPRODUCED WITHOUT PRIOR PERMISSION.
  • Page 6 Same maximum and minimum limits as HI_D_LONG (40004-5). Default: 500. If totalizer, see TABLE 2. HYS1_LONG_MSW Alarm 1 hysteresis (most significant word) 40013 12 R/W www.seneca.it ALL RIGHTS RESERVED. NO PART OF THIS PUBLICATION MAY Doc: MI-00550-0-EN Rev. 1 Page 6...
  • Page 7 4 = Alarm on the maximum held threshold (does not automatically reset). HI_T_LONG_MSW Frequency measurement display value corresponding 40020 19 R/W to output maximum value (most significant word). www.seneca.it ALL RIGHTS RESERVED. NO PART OF THIS PUBLICATION MAY Doc: MI-00550-0-EN Rev. 1 Page 7 BE REPRODUCED WITHOUT PRIOR PERMISSION.
  • Page 8 1 = The totalizer decreases by one unit at each rising edge of the digital input. Bit [11:8] Sets the type of retransmitted output: www.seneca.it ALL RIGHTS RESERVED. NO PART OF THIS PUBLICATION MAY Doc: MI-00550-0-EN Rev. 1 Page 8...
  • Page 9 Measurement of the frequency in scale 0 – 10000. 40048 Measurement of the frequency in scale 0 – 10000. It is 0: if the value displayed on the FREQ_LONG www.seneca.it ALL RIGHTS RESERVED. NO PART OF THIS PUBLICATION MAY Doc: MI-00550-0-EN Rev. 1 Page 9 BE REPRODUCED WITHOUT PRIOR PERMISSION.
  • Page 10 1: The events (rising edges of the digital input) occur with too high a frequency and the instrument temporarily suspends the measurement. Bit 0 1: Damaged calibration eeprom. Contact Seneca srl to solve the problem. COMANDI Sends commands to the module. 40050 49 R/W...