QUALITROL AKM345 GEN3 OTIWTI
40-08847-00-Rev001

3.4 SCADA

4 - 20 mA output signal
0 – 5 V output signal
24 Volt Power Consumption
Dielectric Isolation: 4-20mA, 0-5V, PT100, Modbus
port
Optional Power Supply: Voltage / frequency; rated 100 – 240 Vac 50/60 Hz, or 125 – 250 Vdc
Optional Power Supply: Voltage operating range
Optional Power Supply:
MAINS port
Optional Power Supply: fusing
Optional Power Supply; environmental
EMC immunity
EMC emissions
Terminal wiring: SCADA

4. Safety

4.1 General Warnings

Operation outside of the intended use shall not be the responsibility of Qualitrol.
Refer to the installation manual for mounting details, and adjustment of the switches.
DO NOT APPLY HEAT TO THE THERMOMETER SENSOR BULB AT TEMPERATURES WHICH EXCEED THE
MAXIMUM RANGE OF THE DIAL.
www.qualitrolcorp.com
TM
Instruction Manual
Maximum 500 Ohms load
Minimum 10k Ohm load
Maximum current < 0.25 Amp.
500 Vac to Ground for 60 seconds
Per EN 60255-1; 80 to 110% of rated
Dielectric Isolation-
2000 Vac to Ground for 60 seconds
Internal 5 x 20 mm; T2A; 250V
IP20
Per EN 61000-6-5; Substation category, interface 4
Per IEEE C37.90.1,2,3
Per EN55011; Class A
0.5 – 1.5mm sq (16-20 AWG)