Summary of Contents for Sonifex Audiophile Dante AVN-GPIO
Page 1
® Audiophile Dante Interfaces AVN-GPIO GPIO to LAN Transceiver Manufacturers of Audio Products for AV, Installed Sound, Broadcast Radio & Broadcast TV...
Page 2
Information in this document is subject to change without notice and does not represent a commitment on the part of the vendor. Sonifex Ltd shall not be liable for any loss or damage accordance with the provisions of this Contract. A reference to the consent, whatsoever arising from the use of information or any error contained in this manual.
Page 3
(WEEE). out in Condi�on (a). The policy of Sonifex Ltd is to comply with all applicable laws of all Subject to Condi�on (e) no representa�on, condi�on, warranty or jurisdic�ons having authority over Sonifex’s business, including the WEEE other term, express or implied (by statute or otherwise) is given by the direc�ve.
AVN-DIO09 Handbook Event Mode Virtual Inputs Adding Ouputs Physical Outputs Normal Mode Trigger Mode Virtual Outputs Relay Outputs Power DC Output Source System Update Firmware Reboot or Factory Reset 4. UDP Commands 5. Bootstrap Mode Forcing Bootstrap Mode Upgrading Firmware in Bootstrap mode 6.
Page 6
It has 10 configurable GPIO’s, 8 of which can be used for PTP based programming, together with a relay. It provides virtual GPIO that allow the device to trigger or be triggered by other Sonifex devices on the network using virtual GPIO without the need for extra wiring (virtual GPIO communica�on occurs via the Ethernet connec�on).
Page 7
Actual Subnet Mask The current subnet mask. In the case that the IP address is unknown, the ac�ve IP address for the network port can be found using the Sonifex Service Discovery tool, Addressing Mode available here: The current address mode, either sta�c or dynamic.
Page 8
The web server on the unit is adver�sed as an Avahi / Bonjour service so tools like Sonifex Service Discovery or avahi-browse will be able to discover the address and port number being used by the web server on the unit.
Page 9
AVN-GPIO Handbook Offset Sets the Time to Live for PTP packets. This is the maximum number of hops a When this device is a slave, this indicates the current difference in PTP packet can perform before being removed from the network. nanoseconds between this devices clock and the master’s clock.
AVN-GPIO Handbook GPIO Adding Inputs The GPIO page can be used to configure and monitor the inputs and outputs Inputs can be added by pressing the add bu�on next to ‘INPUTS’. A new of the device. window �tled ‘Add Input’ will be displayed. The input type can be selected here, the input can be one of the following: •...
AVN-Portal could be used. The output type can be selected here, the output can be one of the following: The field ‘Ember Port’ should always be set to 9000 for Sonifex devices. • Physical – Used to pull a physical pin to ground when ac�ve.
The Ember+ provider and tree informa�on is adver�sed on the network via mDNS, this allows other Sonifex devices such as the AVN-Portal, AVN-CU, and DC Output Source AVN-PXH12, to automa�cally discover and add these virtual outputs to their Select between the system DC supply or the DC input supply.
The IP address of the device must be known, the Sonifex Service Discovery Applica�on can be used to find the IP address of the device. Many TFTP clients are available, on Microso�...
Need help?
Do you have a question about the Audiophile Dante AVN-GPIO and is the answer not in the manual?
Questions and answers