Summary of Contents for DELTA DORE CS 8000 TYXAL +
Page 1
CS 8000 TYXAL + Alarm system User guide * Up to 10 years valid under the conditions of use specified in the installation instructions and the General Conditions of Sale.
Warnings Contents 1. How does your alarm system work? ..............................6 We recommend you read this installation guide carefully before any use. 1.1 Presentation..............................................6 • The battery life specified is for normal use. 1.2 Products of the range ..........................................7 • It is advisable to use a touch screen keypad (CLT 8000 TYXAL+) for all configuration operations on 1.3 Home automation functions .........................................9 the installation.
Page 3
Contents 8. Associate home automation functions ............................64 3.6 Zone management ..........................................38 3.6.1 Assigning a product to a zone (1 to 8) ................................38 8.1 Associating a control system receiver (e.g. TYXIA 6410)............................64 3.6.2 Naming the zone ........................................38 8.2 Associating a roller shutter receiver (e.g.
1. How does your alarm system work? 1.1 Presentation 1.2 Products of the range The alarm system is used to monitor a home by means of intrusion detectors (infrared, dual technology or door/window magnetic contacts, etc.) and technical defect detectors (smoke, water, mains power failure, etc.) Max.
1. How does your alarm system work? SEF2 TYXAL+ outdoor siren 1.3 Home automation functions The loud sound of the siren will alert your neighbours in the The home automation functions are used to combine the "Alarm" application event of intrusion. with the other "Thermal"...
Each product regularly sends a radio message to the alarm control unit to confirm that it is working correctly. The DELTA DORE alarm system complies with European standard EN 50131 and ensures quality and reliability for you: If the alarm control unit is no longer receiving messages from a product, it triggers a “Monitoring” defect.
1. How does your alarm system work? 1.11 Operation by independent zone • Pre-alarm zone Associated with a detector, the pre-alarm zone is used The zones are used to protect part of the home. to dissuade intrusion attempts. The management of these zones is fully separate. Example: An outside detector reports a presence to the One or more zones can be on at the same time (e.g.
2. Alarm control unit installation 3. Activation with a CLT 8000 TYXAL+ touch screen keypad TYXAL+ If you do not have a CLT 8000 touch screen keypad on your 2.1 Alarm control unit location installation, refer directly to Chapter 4. - On a flat surface, with enough space all around for installation and opening the battery cover.
3. Activation with a CLT 8000 TYXAL+ touch screen keypad Maintenance mode is used to perform the activation, maintenance and diagnostic operations. 3.2.3 Simplify the activation • Deactivation of the maintenance mode signals 3.2 Maintenance mode The switch to maintenance mode automatically and briefly activates the indoor siren of the alarm control unit as well as a transmitter call 3.2.1 Entering maintenance mode cycle.
3. Activation with a CLT 8000 TYXAL+ touch screen keypad • The alarm control unit must be in maintenance mode. Briefly press the outer button (T1) of the transmitter. The TTRTC TYXAL+, TTGSM, transmitter beeps once when the button is pressed, then beeps again to •...
3. Activation with a CLT 8000 TYXAL+ touch screen keypad 3.4 Access codes (Create - Change - Delete) 3.4.2 Creating or changing a code from the installer code ❶ Enter the installer code (default 6-digit code can be found on a label on the back of the control unit) and 3.4.1 General confirm with OK.
3. Activation with a CLT 8000 TYXAL+ touch screen keypad 3.5 Personalising the installation 3.5.4 Weekly programming The programming can automate the operations for 3.5.1 Setting the clock Automatic operation 25/11/14 12:48 activate/deactivate your system. enabled ❶ Enter the installer code (default 6-digit code can be found on a label Examples: on the back of the control unit) and confirm with OK.
3. Activation with a CLT 8000 TYXAL+ touch screen keypad The following table shows the product functions that can be personalised by 3.5.7 Naming the products the touch screen keypad (menu: Installation > Products > Configure). ❶ Enter the installer code (default 6-digit code can be found on a label on the back of the control unit) and confirm with OK.
3. Activation with a CLT 8000 TYXAL+ touch screen keypad 3.5.8 Activate/deactivate tamper alarm 3.5.11 Button beeps Reminder: To guarantee NF&A2P certification, the tamper alarm must be ❶ Enter the installer code (default 6-digit code can be found on a activated.
3. Activation with a CLT 8000 TYXAL+ touch screen keypad 3.5.15 Sound levels 3.5.16 Exit time for the installation This is the time between activating the system (ON) and the time Setting the sound levels applied to the CS 8000 TYXAL+ alarm when the intrusion detectors are genuinely enabled.
3. Activation with a CLT 8000 TYXAL+ touch screen keypad 3.5.18 Confirmation ON/OFF 3.5.20 Anti-jamming The Confirmation ON/OFF function is used to defer activations The anti-jamming function is used to trigger an intruder alarm or deactivations of the system for a short cycle if there is any wireless jamming attempt on the installation time.
3. Activation with a CLT 8000 TYXAL+ touch screen keypad 3.5.22 Creating phone numbers 3.5.23 Editing or deleting a phone number ❶ Enter the installer code (default 6-digit code can be found on a If a transmitter is present on the installation, you must label on the back of the control unit) and press OK to confirm.
3. Activation with a CLT 8000 TYXAL+ touch screen keypad ❻ Parameter settings 3.5.24 Incoming calls Enter the parameters provided by the remote monitoring operator. Incoming calls are calls made from a telephone to your telephone transmitter. Main number You can specify the number of rings required before the PSTN Specify the main number supplied by the remote monitoring transmitter picks up the line.
3. Activation with a CLT 8000 TYXAL+ touch screen keypad 3.5.26 Maintenance call 3.5.28 SIM card A call cycle is triggered each time the system is switched This menu is used to enter the PIN code of the SIM card to activate it to maintenance mode.
3. Activation with a CLT 8000 TYXAL+ touch screen keypad 3.6 Zone management 3.6.3 Viewing the zones 3.6.1 Assigning a product to a zone (1 to 8) This menu is used to check the list of products associated with a zone. Only the detectors and access codes can be associated with an operating zone (up to 8 separate zones).
Page 21
3. Activation with a CLT 8000 TYXAL+ touch screen keypad 3.6.5 Deleting a zone 3.6.7 Creating a common zone • A zone can only be deleted if it has no associated product. The common zone is directly dependent on the status of the other zones.
Page 22
3. Activation with a CLT 8000 TYXAL+ touch screen keypad ❹ Press the button of the detector to test (❷). 3.7 Door chime function Its identifier is displayed on the screen. The door chime function is used, by associating it with a door/window Confirm with OK.
Page 23
3. Activation with a CLT 8000 TYXAL+ touch screen keypad 3.8.4 Testing a DCP TYXAL+ impact detector or a DCS TYXAL+ , DF or DU detector ❶ Set the control unit to maintenance mode (see "Maintenance mode" chapter). ❷ On the detector: - Press the TEST button on the transmitter.
Page 24
3. Activation with a CLT 8000 TYXAL+ touch screen keypad 4. Activation without a CLT 8000 TYXAL+ touch screen keypad 3.9 Activating/Deactivating a product 4.1 Activating for the first time A product can be deactivated locally with a CLT 8000 TYXAL+ touch screen keypad or remotely via a telephone ❶...
Page 25
4. Activation without a CLT 8000 TYXAL+ touch screen keypad 4.2 Maintenance mode 4.2.2 Exiting maintenance mode Maintenance mode is used to perform the activation, maintenance and diagnostic operations. • The products must be closed (no tamper alarm in progress). The alarm control unit is switched to Maintenance mode by a control device: keypad (apart from outdoor keypad), remote •...
Page 26
4. Activation without a CLT 8000 TYXAL+ touch screen keypad 4.3.3 Step 3: Confirm on the product to be associated 4.3 Adding a product • Before switching the alarm control unit to maintenance mode, the system must be deactivated (OFF). TL 2000 TYXAL+ •...
Page 27
4. Activation without a CLT 8000 TYXAL+ touch screen keypad 4.4 Access codes (Create - Change - Delete) Briefly press the outer button (T1) of the transmitter. The TTRTC TYXAL+ , TTGSM, transmitter beeps once when the button is pressed, then beeps again to TYDOM 2.0 telephone confirm the association.
Page 28
4. Activation without a CLT 8000 TYXAL+ touch screen keypad 4.4.3 Changing an access code 4.4.5 Deleting all access codes With this operation, all the "user" codes are deleted and the ❶ Enter the installer code (by default: 123456). "installer" code is set to its default value (default 6-digit code can be found on a label on the back of the control unit).
Page 29
4. Activation without a CLT 8000 TYXAL+ touch screen keypad 4.6 Zone management 4.6.2 Assigning a product to a zone (1 to 2) from a TL 2000 TYXAL+ remote control 4.6.1 Assigning a product to a zone (1 to 8) from a CLS 8000 TYXAL+ simple keypad To control zones 1 or 2, buttons 1 or 2 of the remote control must be configured in "Mode A"...
Page 30
4. Activation without a CLT 8000 TYXAL+ touch screen keypad 5. Configuring a CLE 8000 TYXAL+ outdoor keypad 4.7 Testing the installation Before using your keypad, you must: • If it controls the alarm system, Once started, the Test mode of a detector lasts for 4 minutes. During this time, associate it with the alarm control unit (see §...
Page 31
6. Configuring a TL 2000 TYXAL+ remote control 6.2 Associating buttons 1 and 2 Deactivation You can activate or deactivate the alarm system with the Activation the alarm remote control. with a control system receiver Depending on the configuration defined with your installer, buttons 1 and 2 can be programmed and have Button 1 Button 2...
Page 32
7. Video Function The video function of the alarm system is provided by an infrared motion detector and TYXAL+ DMBV video associated with a TYDOM 2.0 transmitter. These 2 products must also be associated with the system. Etape 3 : Associate the TYXAL+ DMBV to the system If an intruder is detected, an alarm is triggered and takes a 5-second Maintenance video.
8. Associate home automation functions 8.1 Associating a control system receiver (e.g. TYXIA 6410) 8.3 Associating a TYMOOV wireless roller shutter motor • You want to delay the alarms, status of the system or the • You want the roller shutters to close automatically when the alarm system is switched on operations for activating or deactivating the system via an offset lighting: To associate the Rollia motor, please consult its instructions.
9. Associating a REP TYXAL+ repeater 10. Deleting products Used when wireless propagation can be affected (distance, disrupted 10.1 From the CS 8000 TYXAL+ alarm control unit environment, nature of partitions, etc.), it can repeat the radio signal to remote products. 10.1.1 Delete the control devices If the repeater is already associated with the alarm control unit, go directly to step 2.
10. Deleting products 11. Restoring factory settings (Initialisation) 10.2 From a CLT 8000 TYXAL+ touch screen keypad 11.1 Initialising the CS 8000 TYXAL+ alarm control unit 10.2.1 Deleting a product This operation deletes all the wireless associations and access codes. The settings are set to their default value. ❶...
11. Restoring factory settings (Initialisation) 11.5 Initialising a LB 2000 TYXAL+ badge reader 11.8 Initialising a door/window magnetic contact This operation deletes the wireless associations and the This operation is the same for the following door/window programming of buttons 1 and 2. magnetic contacts: TYXAL+ DO, MDO, DOI PVC The associated badges are not deleted.
11. Restoring factory settings (Initialisation) 12. Summary of LEDs, buttons and audible signals 11.10 Initialising a mains power failure detector The alarm control unit can only be opened if it is in maintenance mode (or without any association), LED A This operation deletes the wireless associations.
Specific technical Technical error • As soon as a technical defect arises. alarm tone Some products use specific battery units, available in the Delta DORE catalogue: DELTA DORE Relevant product or products Description • CS 8000 TYXAL+ siren alarm control unit •...
Page 39
- Applicable standards EN 50131-1 grade 2, EN 50131-5-3, RTC 50131-3, EN 50131-4, RTC 50131-4, EN 50131-6, RTC 50131-6. DELTA DORE shall not be held liable for an premature - Sealing possible by polymerising label 12.7 x 25.4 (tamper proof) - P/N 1730066 wear on the batteries due to any use not compliant with the one described above.
Page 40
15. Troubleshooting This section is intended to help you quickly solve the most common problems that you may encounter with your alarm system when installing or using it. The alarm control unit refuses to exit All the events can be viewed in the Histories menu. Monitoring problem If in doubt, if the problem persists or if it is not in this list, please contact our customer Maintenance mode...
Page 41
The CE conformity declaration for this equipment is available on request from: Service “Infos techniques” DELTA DORE - Bonnemain - 35270 Combourg (France) E-mail: info.techniques@deltadore.com Because of changes in standards and equipment, the characteristics given in the text and the illustrations in this document are not binding unless confirmed...
Need help?
Do you have a question about the CS 8000 TYXAL + and is the answer not in the manual?
Questions and answers