Warnings Contents We recommend you read this user guide carefully before any use. 1. How does your alarm system work?....................45 • The battery life specified is for normal use. 1.1 Presentation ..................................45 1.2 Operation by independent zone ............................46 1.3 Exit timer ..................................46 1.4 Entrance timer................................47 1.5 Intruder alarm procedure ..............................47 1.6 Home automation functions ............................47...
Contents 1. How does your alarm system work? 1.1 Presentation 7. Changing your access code ......................65 7.1 General ..................................65 The alarm system is used to monitor a home by means of intrusion detectors (infrared, dual technology or door/window 7.2 Using your touch screen keypad ...........................65 magnetic contacts, etc.) and technical defect detectors (smoke, water, mains power failure, etc.) 7.3 Using your simple keypad .............................65 The system is activated or deactivated by means of a remote control, a keypad or badge reader, a telephone transmitter...
1. How does your alarm system work? 1.2 Operation by independent zone 1.4 Entrance timer With the remote control or the badge reader, you can place zones You are entering a zone monitored by a motion Beep...beep... 1 and 2 under surveillance. A touch screen keypad or simple detector.
2. Use with your touch screen keypad 2.1 Description 2.2 Info menu Outdoor temperature The following screens are provided for information. Date 25/11/15 12:48 Signals Screen Time part an event 25/11/15 12:48 25/11/15 12:48 25/11/15 12:48 Info Battery defect Open entry 2 defects detector op.
2. Use with your touch screen keypad 2.4 Activating the system 2.6 Override operation • Complete activation For example, this is used to activate the system even if an entry remains open or a product shows a defect (dead battery, etc.). Ê...
3. Use with the remote control 3.2 Activating the system You can activate or deactivate the alarm system with the remote control. Depending on the configuration defined with your installer, only the buttons can be programmed and Depending on the installation settings, the alarm control Activation Deactivation have different functions.
3. Use with the remote control Beep, beep, beep 3.4 Override operation 3.7 Clearing defects Each time the system is activated or deactivated, the alarm For example, this function is used to activate the system even control unit will inform you that an event (or defect) is stored by Ê...
4. Use with the badge reader 4.3 Deactivating the system You can activate or deactivate the alarm system with the badge Activation reader. Depending on the configuration defined with your installer, only Depending on the installation settings, the alarm control buttons can be programmed and have different unit will or will not emit beeps to confirm the activation or Deactivation...
4. Use with the badge reader 5. Use with your simple keypad 4.5 Triggering of a discreet emergency The keypad is used to activate or deactivate your system fully or by zone via an access code. alarm You also have a direct access SOS button to warn relatives that you are in danger.
5. Use with your simple keypad 5.3 Override operation 5.5 Triggering of an emergency alarm with siren For example, this function is used to activate the system even if an entry remains open or if a product shows a defect (dead Press and hold the SOS button for 2 seconds.
6. Use with your outdoor keypad 6.3 Override operation The keypad is used to activate or deactivate your system fully or by zone via an access code. For example, this function is used to activate the Wrong code entered: The keypad is locked for 90 seconds system even if an entry remains open or if a product after five attempts to enter the wrong code.
6. Use with your outdoor keypad 7. Changing your access code 6.5 Controlling a control system 7.1 General If you have associated control systems to the keypad, you can We recommend that you keep the access codes confidential (6 digits). Avoid codes such as "date of birth" or series of control them after entering the 4-digit access code dedicated to easy to reproduce digits "222222", "234567", etc.
8. Personalising the products with your touch screen keypad 8.4 Weekly programming Before personalising your system, you must shut it down. Automatic operation The programming can automate the operations for 25/11/14 12:48 activate/deactivate your system. enabled 8.1 Setting the clock Examples: Enter your code - You can protect your ground floor each night.
8. Personalising the products with your touch screen keypad 8.5 Name the products The following table shows the product functions that can be personalised by the touch screen keypad (menu: Use > Products > Configure). Ê Enter the user code (e.g. 456789) and confirm with OK. Access code 25/11/14 12:48...
8. Personalising the products with your touch screen keypad 8.6 Button lighting 8.9 Sound levels The Button lighting, Button beeps and Brightness button Setting the sound levels applies to the alarm control unit and settings only concern the touch screen keypad you use for these the outdoor and indoor sirens.
8. Personalising the products with your touch screen keypad 8.10 Call numbers 8.11 Incoming calls Incoming calls are calls made from a If a transmitter is present on the installation, you must telephone to your telephone transmitter. programme the numbers that will be called in the event of an You can specify the number of rings required before the PSTN alarm or technical defect.
8. Personalising the products with your touch screen keypad 9. Zone management 8.13 SMS alert to relatives (only with a 9.1 Naming the zone GSM transmitter) For naming the zones, we recommend you use one of the labels proposed in the list (see § 7.5). This function is used to send an SMS to a programmed If you have a telephone transmitter on your installation, it will number if the system is activated or deactivated.
11. Testing your installation 11.1 Test under operating conditions Test the door/window magnetic contacts Test your installation under actual operating conditions by triggering an alarm with each of your detectors. Beep During this test, you must take the “exit timer” into account to achieve effective surveillance (up to 90 seconds).
12. Activating/Deactivating a product 13. Summary of LEDs and audible signals A product can be deactivated locally with a touch screen keypad or remotely via a telephone transmitter (e.g. a detector that generates intrusions because of an incorrectly closed window). When a product is deactivated, some of its functions are no longer covered by the alarm control unit, but others remain enabled.
• There is a tamper alarm problem on one of the system's products. zone. Please consult us if you are in any doubt installation's products. Some products use battery units specific to Delta Dore. - Check the tamper alarms. Door/window magnetic contact Lithium battery precautions same manufacturer and having the same type.
Page 22
Delta Dore hereby declares that the equipment complies with the essential requirements and other rele- vant provisions of R&TTE directive 1999/5/EC. The CE conformity declaration for this equipment is available on request from: Service “Infos techniques” DELTA DORE - Bonnemain - 35270 Combourg (France) E-mail: info.techniques@deltadore.com...
Need help?
Do you have a question about the CS 8000 TYXAL+ and is the answer not in the manual?