Advertisement

Quick Links

INSTRUCTION MANUAL
Cordless Cleaner
DCL286F
Read before use.

Advertisement

Table of Contents
loading

Summary of Contents for Makita DCL286ZWX1

  • Page 1 INSTRUCTION MANUAL Cordless Cleaner DCL286F Read before use.
  • Page 2: Specifications

    WARNING • This appliance can be used by children aged from 8 years and above and persons with reduced physical, sen- sory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruc- tion concerning use of the appliance in a safe way and understand the hazards involved. •...
  • Page 3: Intended Use

    19. Do not use a battery pack or appliance that Intended use is damaged or modified. Damaged or modified batteries may exhibit unpredictable behaviour The tool is intended for collecting dry dust. resulting in fire, explosion or risk of injury. 20.
  • Page 4 It will A battery short can cause a large current also void the Makita warranty for the Makita tool and flow, overheating, possible burns and even a charger. breakdown.
  • Page 5: Functional Description

    If no improvement can be found by restoring protection system, then contact your local Makita Service Center. To remove the battery cartridge, slide it from the tool Indicating the remaining battery while sliding the button on the front of the cartridge.
  • Page 6 Lighting up the lamp Indicator lamps Remaining capacity CAUTION: Do not look in the light or see the Lighted Blinking source of light directly. 75% to 100% To turn on the lamp, push the suction power change button. The lamp goes off in approximately 10 seconds. 50% to 75% While the cleaner is running, the lamp turns on.
  • Page 7: Parts Description

    PARTS DESCRIPTION Fig.6 Mesh filter 250 mL dust case 400 mL dust case Cyclone body (Optional accessory) (Optional accessory) HEPA filter (Filter frame High performance Sponge sheet Cleaner body filter (Filter frame in in white color) (Optional gray color) (Optional accessory) accessory) Hand strap (Country...
  • Page 8: Operation

    To remove attachment, pull it off the cleaner while Cleaning (Suction) pressing and holding the arms of the release button. Nozzle With 250 mL dust case only Attach the nozzle to clean off tables, desks, furniture, etc. The nozzle slips on easily. Fig.8 ►...
  • Page 9 For picking up dust on a floor in a standing position, it is You can store the sash nozzle in the nozzle holder. convenient to attach the extension wand to the cleaner. Fig.13 ► 1. Nozzle holder 2. Sash nozzle Be careful not to trap finger(s) CAUTION: Fig.16...
  • Page 10: Maintenance

    Never use gasoline, benzine, thinner, alcohol or the like. Discoloration, deformation or cracks may result. To maintain product SAFETY and RELIABILITY, repairs, any other maintenance or adjustment should be performed by Makita Authorized or Factory Service Centers, always using Makita replacement parts. 10 ENGLISH...
  • Page 11 Cyclone unit and filters NOTE: Dust may fly out when the cyclone unit is disassembled. It is recommended to place a garbage Dust off and clean out inside the NOTICE: bag underneath the cyclone unit. cyclone unit and filters, when suction perfor- mance becomes less effective regardless of the Dust off inside the cyclone unit and filter.
  • Page 12: Hepa Filter

    High performance filter NOTE: Avoid fastening the attachment end (rubber sealing ring) of high performance filter when hanging it up for drying. Optional accessory Hold the mounting end of high performance filter Disassemble the cyclone unit from the cleaner body. and squeeze it back into the cleaner body.
  • Page 13 Wipe and shake dust off the high performance Hold the mounting end of HEPA filter (covered with prefilter and HEPA filter by hand. high performance prefilter) and squeeze it back into the cleaner body. Fig.32 Fig.35 Wash the high performance prefilter and HEPA ►...
  • Page 14 Wipe and shake dust off the sponge sheet by Place the sponge sheet back in the original hand. position. Make sure that the left and right edges of the sponge sheet are secured with stoppers and no gap between the sponge sheet and suction opening. Fig.38 Wash the sponge sheet in soapy water when it is clogged with dust and dirt.
  • Page 15 Disassemble the mesh filter into three compo- Condition-based maintenance nents: prefilter, tubular sponge filter and mesh pipe. Squeeze the guide stoppers on top of the mesh Clean the mesh filter in the cyclone NOTICE: pipe together. unit when they become clogged. Continuing use in Pass the guide stoppers down through the guide the clogged condition may result in heating or motor hole on top of the prefilter.
  • Page 16 Wash the filters and mesh pipe in soapy water Attach the mesh filter back into the cyclone body aligning the hooks on the mesh filter with the ports on when they are clogged with dust and dirt. Dry them out thoroughly in the shade before use.
  • Page 17 Press and hold the guide stopper on the inlet pipe Insert the inlet pipe back in place until it is securely down through the locking hole on the cyclone body locked. using the hand tool with a point. Then detach the inlet pipe from the cyclone body.
  • Page 18: Troubleshooting

    OPTIONAL ACCESSORIES CAUTION: These accessories or attachments are recommended for use with your Makita tool specified in this manual. The use of any other accessories or attachments might present a risk of injury to persons. Only use accessory or attachment for its stated purpose.
  • Page 20 Jan-Baptist Vinkstraat 2, Makita Europe N.V. 3070 Kortenberg, Belgium 3-11-8, Sumiyoshi-cho, Makita Corporation Anjo, Aichi 446-8502 Japan 885A27-221 www.makita.com 20221111...

This manual is also suitable for:

Dcl286f