Table 1. Features and specifications
Microprocessor:
v AMD Opteron
processor
v 1024 KB Level-2 cache
Note: Use the Configuration/Setup
Utility program to determine the type
and speed of the microprocessors in
your server.
Memory:
v Type: Error correcting code
(ECC), double-data rate (DDR)
SDRAM, registered DIMMs with
Chipkill
memory protection
– Minimum: 1 GB
– Maximum: 6 GB
v Four interleaved slots with
standard microprocessor (required
installation in pairs)
v Two interleaved slots with optional
microprocessor
Drives:
v CD-ROM: Slim IDE (standard)
v Hard disk drives:
– Slim-high 3.5-inch drives,
hot-swap SCSI or
non-hot-swap IDE (drive
capacity and speed vary with
model)
– Maximum: Two
Expansion slots:
v One full-length adapter slot
supports up to 100 MHz/64-bit
PCI-X adapters (bus 3)
v One half-length adapter slot
supports up to 100 MHz/64-bit
PCI-X adapters (bus 3)
v Supports 3.3 V or universal
adapters only
Video controller:
v ATI RageXL video controller on
system board
v Compatible with SVGA
v 8 MB SDRAM video memory
Power supply:
One 411 watt (115-230 V ac)
Size:
v Height: 43 mm (1.69 in.)
v Depth: 660 mm (25.98 in.)
v Width: 440 mm (17.32 in.)
v Weight: approximately 12.7 kg (28
lb) when fully configured
Integrated functions:
v Baseboard management controller
v One single-channel LSI Ultra320
SCSI controller
v Two Broadcom 10/100/1000
Ethernet controllers (dual-port
design) with Wake on LAN
support
v Four Universal Serial Bus (USB)
ports
v One serial port
v One video port
Note: The baseboard management
controller is also known as the
service processor.
Acoustical noise emissions:
v Declared sound power, idling: 6.5
bels
v Declared sound power, operating:
6.5 bels
Environment:
v Air temperature:
°
– Server on: 10
to 35°C (50.0° to
95.0°F). Altitude: 0 to 914 m
(2998.7 ft)
– Server on: 10° to 32°C (50.0° to
89.6°F). Altitude: 914 m (2998.7
ft) to 2133 m (6998.0 ft)
– Server off: 10° to 43°C (50.0° to
109.4°F). Maximum altitude:
2133 m (6998.0 ft)
v Humidity:
– Server on: 8% to 80%
– Server off: 8% to 80%
v Airflow rates:
– Minimum: 28 CFM
– Maximum: 47 CFM
Heat output:
Approximate heat output in British
thermal units (Btu) per hour for dual
multiprocessor configurations:
v Minimum configuration: 409 Btu (120
watts)
v Maximum configuration: 1366 Btu
(400 watts)
Electrical input:
v Sine-wave input (50-60 Hz) required
v Input voltage low range:
– Minimum: 100 V ac
– Maximum: 127 V ac
v Input voltage high range:
– Minimum: 200 V ac
®
– Maximum: 240 V ac
v Input kilovolt-amperes (kVA),
approximately:
– Minimum: 0.120 kVA
– Maximum: 0.400 kVA
Notes:
1. Power consumption and heat output
vary depending on the number and
type of optional features installed
and the power-management optional
features in use.
2. These levels were measured in
controlled acoustical environments
according to the procedures
specified by the American National
Standards Institute (ANSI) S12.10
and ISO 7779 and are reported in
accordance with ISO 9296. Actual
sound-pressure levels in a given
location might exceed the average
values stated because of room
reflections and other nearby noise
sources. The declared sound-power
levels indicate an upper limit, below
which a large number of computers
will operate.
5
Chapter 1. Introduction

Advertisement

Table of Contents
loading

This manual is also suitable for:

8835

Table of Contents