Summary of Contents for Mercury MTM01

  • Page 1 Item ref: 600.100UK MTM01 Digital Multimeter User Manual...
  • Page 2 Disconnect circuit power and discharge all high-voltage capacitors before testing resistance, continuity, diodes.F • Replace the battery as soon as the battery indicator appears. A low battery may produce false readings that can lead to electric shock and personal injury. 600.100UK MTM01 User Manual...
  • Page 3 “1” or “OL” is displayed Operating Environment: 0ºC-40ºC, at <80%RH Storage Environment: -10ºC-50ºC, at <85%RH Power: 9Vdc (1 x PP3 battery supplied) Low battery indication: “ ” is displayed Dimensions: 190 x 90 x 33mm Weight: 227g (including battery) 600.100UK MTM01 User Manual...
  • Page 4 Power HOLD Button Button Range switch hFE/mA terminal terminal INPUT terminal terminal Multi-function adapter 600.100UK MTM01 User Manual...
  • Page 5: Resolution Accuracy

    0.1mV ±(0.5% of rdg + 3D) 10mV ±(0.8% of rdg + 5D) 200V 100mV 600V ±(1.0% of rdg + 5D) Input Impedance: 10MΩ Overload Protection: 600V DC or 600V AC rms Max. Input voltage: 600V DC 600.100UK MTM01 User Manual...
  • Page 6: Range Description

    2.8V Overload Protection: 250V DC/AC rms DC Current RANGE RESOLUTION ACCURACY ±(1.8% of rdg + 2D) 20mA 10uA 200mA 100uA ±(2.0% of rdg + 2D) 10mA ±(2.0% of rdg + 10D) Voltage Drop: 200mV 600.100UK MTM01 User Manual...
  • Page 7 20MΩ 10kΩ ±(1.0% of rdg + 10D) 200MΩ 100kΩ Open Circuit Voltage: about 0.5V ( 200MΩ range is 3V) Capacitance RANGE RESOLUTION ACCURACY 20nF 10pF 200nF 100pF ±(4.0% of rdg + 5D) 20uF 10nF 200uF 100nF 600.100UK MTM01 User Manual...
  • Page 8 3. Open the circuit to be measured and connect test leads in SERIES with the load in with current is to measure. 4. Current reading will be displayed on LCD, for DC current measurement, the polarity of the red probe will also be indicated. 600.100UK MTM01 User Manual...
  • Page 9 3. Connect test leads across the capacitor under measure and be sure the polarity of connection is observed. Please Note: • To avoid damage to the Meter, disconnect circuit power and discharge all high-voltage capacitors before measuring capacitance. 600.100UK MTM01 User Manual...
  • Page 10 Identify whether the transistor is NPN or PNP type and locate Emitter, Base and Collector lead. Insert the leads of the transistor to be tested into the proper holes of the transistor test socket of the adaptor. LCD display will show the approximate hFE value. 600.100UK MTM01 User Manual...
  • Page 11 Errors and omissions excepted. Copyright© 2024 AVSL Group Ltd, Unit 2 Bridgewater Park, Taylor Road, Trafford Park, Manchester. M41 7JQ. AVSL (Europe) Ltd, Unit 3D North Point House, North Point Bus. Park, New Mallow Road, Cork, Ireland. 600.100UK MTM01 User Manual...