14
Technical data
Power system
Start-up time from sleep mode
Start-up time
Environmental data
Operating temperature range
Storage temperature range
Humidity (operating and storage)
Relative humidity
Directives
EMC
Magnetic fields
Encapsulation
Shock
Vibration
Drop
Safety (power supply)
Physical data
Camera weight, incl. battery
Battery weight
Camera size (L × W × H)
Tripod mounting
Material
Shipping information
List of contents
Packaging, weight
#T559946; r. BA/41926/41970; en-US
< 4 s.
< 17 s. (IR image, no GUI)
–20°C to +85°C (–4°F to +185°F)
+150°C (+302°F): 15 min.
+260°C (+500°F): 5 min.
–40°C to +85°C (–40°F to +185°F)
IEC 60068-2-30/24 h 95% relative humidity +25°C
to +40°C (+77°F to +104°F) / 2 cycles
95% relative humidity +25°C to +40°C (+77°F to
+104°F) non-condensing
Designed to meet NFPA 1801:2013 specification:
Vibration
Impact acceleration resistance
Corrosion
Viewing surface abrasion
Heat resistance
Heat and flame
Product label durability
EN 61000-6-2:2005 (Immunity)
EN 61000-6-3: 2011 (Emission)
FCC 47 CFR Part 15 B (Emission)
EN 61 000-4-8, Test level 5 for continuous field
(severe industrial environment)
IP 67 (IEC 60529)
25 g (IEC 60068-2-27)
2 g (IEC 60068-2-6)
2 m (6.6 ft.) on concrete floor (IEC 60068-2-31)
CE/EN/UL/CSA/PSE 60950-1
1.1 ±0.05 kg (2.4 ±0.1 lb.)
0.152 kg (0.3 lb.)
120 × 125 × 280 mm (4.7 × 4.9 × 11 in.)
UNC ¼"-20 (adapter needed)
PPSU
Silicon rubber
Aluminium, cast
Flame-resistant magnesium alloy
Infrared camera
Battery (2 ea.)
Battery charger
Hard transport case
Lanyard strap
Neck strap
Power supply
Printed documentation
Retractable lanyard
Tripod adapter
USB cable
5.7 kg (12.6 lb.)
52