Install The Filter; After Installation - PROBOIL PROTHIA PT1130 Installation Manual

Table of Contents

Advertisement

Install the Filter:

1. Find a suitable place to mount the filter cartridge (C8) under the sink, it must be mounted vertically, easily
accessible (to be changed periodically), away from any heat source or electrical connections and close
enough not to exceed the available length of the ¼" plastic pipe (C5, C9) supplied to reach between the tap,
filter and boiler (place the boiler temporarily to help judge the required lengths of ¼" plastic pipe).
2. Using the self-tapping screw (C6) securely fix the filter bracket (C7) to the cabinet wall.
3.
Write the installation date onto the filter label in permanent pen.
4. Clip the filter cartridge (C8) into the bracket (C7) as shown.
You must respect the direction of flow as indicated on the filter cartridge (C8).
5. Measure and then cut required length of ¼" pipe (C5) to connect pushfit (C4) to the filter cartridge (C8) inlet,
allow a small amount of extra length to make it easier to change the filter.
6. Firmly push connect the ¼" pipe (C5) between pushfit (C4) and filter cartridge inlet (C8).
7. Firmly push connect the remaining ¼" pipe (C9) into the filter cartridge outlet (C8).

After Installation:

1. Reconnect the domestic hot and cold water supplies and open hot and cold isolation valves (B6). As the
system starts to refill, check carefully all new water connections for leaks. After the product installation is
complete we recommend you recheck for any slower leaks.
2.
It is normal for new filter cartridges to lose a small amount of loose carbon when first used and will
dissipate with flushing, whilst harmless to consume if the carbon particles are not flushed prior to connection
to the boiler they may partly block the boiler and reduce the flow rate. You must flush the filter for at least 2
litres with cold water or until the water become clear (without black carbon particles).
3. Place the ¼" pipe (C9) from the filter cartridge (C8) outlet into a bowl or bucket.
4. Turn on the 98°C backwards handle fully, keep the lever open until all air is expelled and cold (filtered) water
exits the ¼" pipe (C8) into the bowl, flush a minimum of a further 2 litres of cold (filtered) water through the
¼" pipe (C8). You may notice a discolouration to the water at first, this is loose carbon particles from the
filter it is normal, harmless and will pass with flushing. Continue to flush the filter until the water runs clear.
Once complete turn off the 98°C handle.
5. Please refer to 'PROBOIL.2X User & Installation Guide' for the next steps on how to install the boiler and
connect the tap and filter.
Please leave these instructions for your customer
01/2020

Advertisement

Table of Contents
loading

Related Products for PROBOIL PROTHIA PT1130

Table of Contents