Electrolux Professional TD6-24S Installation Manual

Hide thumbs Also See for TD6-24S:

Advertisement

Quick Links

Installation manual
Tumble dryer
TD6–24S
Compass Pro
Type N3...
438917590/GB, IE
Original instructions
2024.02.09

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TD6-24S and is the answer not in the manual?

Questions and answers

Summary of Contents for Electrolux Professional TD6-24S

  • Page 1 Installation manual Tumble dryer TD6–24S Compass Pro Type N3... 438917590/GB, IE Original instructions 2024.02.09...
  • Page 3: Table Of Contents

    Contents Contents 1 Safety Precautions ..........................5 Additional safety precautions for gas heated tumble dryer .............7 General safety information......................7 Commercial use only........................7 Copyright ..........................7 Symbols............................8 2 Warranty terms and exclusions......................9 3 Technical data...........................10 Drawing ..........................10 Technical data ......................... 11 4 Setup ...............................12 General...........................12 Unpacking ..........................12 Recycling instruction for packaging ...................13...
  • Page 5: Safety Precautions

    Installation manual 1 Safety Precautions • Servicing shall be carried out only by authorized personnel. • Only authorized spare parts, accessories and consumables shall be used. • The machine is not to be used if industrial chemicals have been used for cleaning. •...
  • Page 6 Installation manual • Oil-affected items can ignite spontaneously, especially when exposed to heat sources such as in a tumble dryer. The items become warm, causing an oxidation reaction in the oil. Oxidation creates heat. If the heat cannot escape, the items can become hot enough to catch fire.
  • Page 7: Additional Safety Precautions For Gas Heated Tumble Dryer

    The machine/machines covered by this manual is/are made for commercial and industrial use only. 1.4 Copyright This manual is intended solely for consultation by the operator and can only be given to third parties with the permis- sion of Electrolux Professional AB company.
  • Page 8: Symbols

    Installation manual 1.5 Symbols Caution Caution, hot surface Caution, high voltage Warning, risk of fire / flammable material Danger, crush hazard Read the instructions before using the machine...
  • Page 9: Warranty Terms And Exclusions

    Warranty will be applicable where the customer has used only genuine spare parts and has performed maintenance in accordance with Electrolux Professional user and maintenance documentation made available in paper or elec- tronic format. Electrolux Professional strongly recommends using Electrolux Professional approved cleaning, rinse and descaling agents to obtain optimal results and maintain product efficiency over time.
  • Page 10: Technical Data

    Installation manual 3 Technical data 3.1 Drawing fig.W00530 Operating panel Door opening, ⌀ 687 mm Electrical connection Gas connection Exhaust connection 1335 2085 1310 1240 1085 2185...
  • Page 11: Technical Data

    Installation manual 3.2 Technical data Weight, net Drum volume litres 2 x 423 Drum diameter Drum depth Drum speed 43–44 Rated capacity, filling factor 1:18 (Max. load) 2 x 23.5 Rated capacity, filling factor 1:22 (Recommended load) 2 x 19.2 Heating: Gas 2 x 27.5 Air flow...
  • Page 12: Setup

    Installation manual 4 Setup 4.1 General The principle work flow to setup or install this machine is as follows: 1. Unpacking 2. Positioning/siting, levelling or/and securing the machine. 3. Correcting the fresh air/air intake's size, exhaust duct's size and pipe(s) connections in considering a stand-alone machine or sharing exhaust duct.
  • Page 13: Recycling Instruction For Packaging

    Installation manual 4.3 Recycling instruction for packaging fig.X02460 Fig. Description Code Type Wrapping film LDPE 4 Plastics Corner protection PS 6 Plastics Cardboard packaging PAP 20 Paper Pallet FOR 50 Wood Screw FE 40 Steel Plastic bag PET 1 Plastics...
  • Page 14: Siting

    Installation manual 4.4 Siting The figure shows recommended distance to walls and/or other machines. D=C+B 1= Top view 2 = Side view on built in machine Y = For built-in machines it is recommended that the wall section Y is a removable finish piece. If so, E and F can be 0. fig.X00959A 5–500 mm (Min.
  • Page 15: Connection To Network

    Installation manual 4.5 Connection to network If several machines are to be connected to a network, the knock-outs (A) in the side panels must be removed before installation. A bushing for network cables must be installed from the inside in the right-hand side panel. The bushing must be pushed right through the hole in the left-hand side panel on the side of the machine.
  • Page 16: Securing The Machine

    Installation manual 4.6.1 Securing the machine To ensure steadiness of the machine it is important to fasten the machine to the foundation. Fasten the four fittings (A) to the foundation using four x M10 set screws (B). If the four fittings are not supplied, order kit No.
  • Page 17: Evacuation System

    Installation manual 5 Evacuation system 5.1 Air principle The fan creates low pressure in the machine, drawing air into the drum via the heating unit. The heated air passes through the garments and the drum holes. The air then flows out through a lint filter positioned below the drum. Then the air is evacuated through the fan and exhaust system.
  • Page 18: Exhaust Duct

    Installation manual 5.3 Exhaust duct • Only rigid or flexible metal duct should be used for exhausting. • Plastic ducting is not to be used. • Recommended material for exhaust is galvanized steel. • The duct is not to be assembled with screws or other fastening means that extend into the duct and catch lint. •...
  • Page 19: Shared Exhaust Duct

    Installation manual 5.4 Shared exhaust duct It is recommended that each machine is connected to a separate exhaust duct. When several machines shall use the same exhaust duct the exhaust duct must increase before each machine is added. The individual ducts should enter the main duct at an angle of 45° or less and in the direction of airflow. The recommended diameter increase progression is the one in the table.
  • Page 20: Gas Connection

    Installation manual 6 Gas connection 6.1 Fasten the label Before installing the machine fasten the label “Read the user instructions” on the inside of the door in a suitable place and at the front panel. The label must have the correct country code, choose the correct label from the gas kit. Read the technical instructions before installing the appli-...
  • Page 21: Gas Installation

    Installation manual 6.3 Gas installation The default gas appliances are built to run on GNH (Natural gas) where the machine should be installed at not over than 610 m (2001 ft) high altitude. To run on another gas the gas converting must be done. The gas converting accessories for another gas is in the ac- cessory bag.
  • Page 22: Table Of Pressure And Adjustment

    Installation manual 6.4 Table of pressure and adjustment Liquid petrole- Gas category Inlet pressure Nozzle pres- Nozzle size (⌀ Air reducing/ Label number May be avail- um gas (LPG) (mbar) sure (mbar) restriction plate able in follow- (mm) ing countries Butane mixture 28-30 / No regulation...
  • Page 23: Test Run

    Installation manual 6.5 Test run Note! Before test run the machine, ensure that the air flow/static back pressure has been adjusted accorded to the "Evacuation system" section. Adjust the air flow if necessary. • Loosen the measuring branch screw (2) 1/4 turn; connect a manometer to the measuring branch and make sure the connection is tight to prevent air leakage.
  • Page 24: Converting Instructions

    Installation manual 6.6 Converting instructions • Disconnect the power to the machine. • Demount the back panel. • Demount the air restriction plate (1). • Demount the nozzle (2) and mount the new supplied nozzle. • Re-mount the air restriction plate. fig.X02718 •...
  • Page 25: Data Label

    INJECTOR:Ø 4.60 NATURAL GAS : G20 (INLET PRESS.: 20-25 MBAR, CAL. VAL. 37780 KJ/M3) For safety reasons use only genuine spare parts. Made in Sweden Electrolux Professional AB 341 80 Ljungby, Sweden WXXXXX 9868XXXXXX Product no.: 09XXX / 99XXXXX Serial no.:...
  • Page 26: Electrical Connection

    Installation manual 7 Electrical connection 7.1 Electrical installation The electrical installation may only be carried out by qualified personnel. Machines with frequency-controlled motors can be incompatible with certain types of earth leakage circuit break- er. It is important to know that the machines are designed to provide a high level of personal safety, which is why items of external equipment such as earth leakage circuit breakers are not necessary but is recommended.
  • Page 27: Three-Phase Connection

    Installation manual 7.3 Three-phase connection Demount the upper rear cover panel. Connect the earth and other wires as shown. L1 L2 L3 L2 L3 3NAC L1 L2 L3 N 3NAC 3NAC L2 L3 When the installation is completed remount the cover panel and check: •...
  • Page 28: Electrical Connections

    Installation manual 7.4 Electrical connections Electrical connections Heating alternative Main voltage Heating power Total power Recommended fuse Gas heated 220–240V 3~ 50/60 380–480V 3~ 50/60 230–240V 1~ Total power and recommended fuse does not depend on the heating power in those cases.
  • Page 29: At First Power Up

    Installation manual 8 At first power up When the installation is complete and the power is connected for the first time you will be forced to make the following settings. When one setting is ready you will automatically enter the next one. Follow the instructions on the display. •...
  • Page 30: Function Check

    Installation manual 9 Function check May only be carried out by qualified personnel. A function check must be made when the installation is finished and before the machine can be ready to be used. Whenever a repair has been made, a function check must be performed before the machine can be used again. Check the automatic stop of the machine •...
  • Page 31 Installation manual If the direction is wrong, swap two of the three phases to the left on the connection terminal. fig.7119 Check the heat • Let the machine work for five minutes on a program with heat. • Check that the heating is working by opening the door and feel if there is heat in the drum. Ready to use If all tests are OK the machine is now ready to be used.
  • Page 32: Disposal Information

    Installation manual 10 Disposal information 10.1 Disposal of appliance at end of life Before disposing of the machine, make sure to carefully check its physical condition, and in particular any parts of the structure that can give or break during scrapping. The machine’s parts must be disposed of in a differentiated way, according to their different characteristics (e.g.
  • Page 34 Electrolux Professional AB 341 80 Ljungby, Sweden www.electroluxprofessional.com...

Table of Contents