➤ Make an air inlet vent and an air outlet vent in the outer wall with the size of
249 mm x 490 mm.
When doing so, observe the information in chapter "Preparing the installation"
on page 16.
If the ventilation grill of the air inlet vent cannot be installed flush with the floor of the
niche, install an inlet vent in the floor. Any leaking gas can thus flow downwards.
➤ Make an air inlet vent of at least Ø 40 mm in the floor (fig. 8 1, page 8) behind
the refrigerator near the gas burner.
➤ Shield the end of the opening with a deflector to prevent sludge or dirt from get-
ting inside while driving (fig. 8 2, page 8).
If you have to use a roof vent instead of the air outlet vent:
➤ Cut out a section in the roof. Refer to the roof vent instruction manual for the
required dimensions.
When doing so, observe the information in chapter "Preparing the installation"
on page 16.
5.4
Installing the ventilation grill
I
NOTE
Use exclusively original Dometic ventilation grills to ensure safe opera-
tion.
No. in
fig. 9, page 8
1
2
3
4
➤ Seal the installation frame to make the connection waterproof (fig. 0, page 8).
➤ Insert the installation frame and screw it down tightly (fig. a, page 8). Use all the
fixing holes for this.
➤ Insert the ventilation grill as shown (fig. b, page 9).
EN
Description
Slider
Ventilation grill
Installation frame
Fastening for condensation drain
Installing the refrigerator
19