Ma intenance
j.
If LED combination 7-0 is
being
displayed
(indicating
the
successful
completion
of
the
self test), run DSM for more
extensive troubleshooting.
(Refer
to
the
support- user/DSM
operations
described
in
the HP 300l0A / 30020A Intelligent
Network Processor Diagnostic Procedures Manual.)
k.
If any other combina tion of ligh ted LEDs (not already covered
in steps f through j)
is being displayed as a result of your
having pressed the RESTART switch in step d, replace the
INP
PCA
board
(part
no.
30020-60001).
(See paragraph 5-18,
"Replacement of the PCA Board".)
NOTE
Whe n send ing PCA boards to
the
fac tory
for
replacement,
refer
to
paragraph
5-19,
"Resh ipment
Ins tr uct ions".
Include in the package your noted obser-
vations from step bi
they may be
help-
ful
during
factory-level
trouble-
shooting.
Also, if a
5-0
or
3-0
LED
pattern
was
observed in step b, an INP
dump
file
may
have
been
created
in
PUB.SYS
(labeled INPLOGnn , where nn is
in the range from 00 to
99).
If
they
can
be
located,
these
INPLOG
files
should also be included in
the
package
with
the
defective
equipment.
(See
Appendix B for
further
information
on
the INP dump files.)
5-15. Off-board Loopback Testing
When support-user diagnostic testing is required beyond the
phy-
sical
limits
of the INP PCA board, certain portions of the data
communications network can be synthesized.
A
test
hood
and
a
test
connector
are
included with certain cable options.
These
test attachments are used with the off-board loopback tests
des-
cribed
in
the
HP 30010A / 30020A Intelligent Network Processor
Diagnostic Procedures Manual.
The test hood and
test
connector
are
illustrated in figure 1-1 and listed by part number in table
1-2.
The test attachments are used as follows:
of
Run
With the modem cable disconnected from the edge connector
the
INP
PCA
board, attach the test hood in its place.
Test Group 6 of DSM.
b.
If the test group passes
(indicating
that
the
problem
is
or iginating
from somewhere "farther downstream"), remove the
test hood and reconnect the modern cable to the INP peA board.
Disconnect the other end of the modern cable from
the
modern,
and
attach the test connector to the modern cable in place of
the modern.
Repeat Test Group 6 of DSM.