Components and Their Functions

6.1
Multi Display
(2)
(1)
(6)
(7)
No.
Name
(1) Main display
Indicates the measured value.
Indicates the result of judgment and
HI
turns on if the measured value > HI
judgment value.
Indicates the result of judgment and
Judgment
(2)
GO
turns on if LO judgment value ≦ the
indicators
measured value ≦ HI judgment value.
Indicates the result of judgment and
LO
turns on if the measured value < LO
judgment value.
ME Turns on if "digital zero backup" is on.
Turns on if "peak hold/valley hold/
PH
peak - valley hold" is on.
Function
(3)
DZ
Turns on if "digital zero" is on.
indicators
Turns on if remote control is being
RE
performed through RS-232C or RS-
485 interface.
Indicates the HI side judgment value.
Indicates the item in the maximum/
(4) Sub-display 1
minimum/(maximum-minimum)/input
value monitoring mode.
Indicates the LO side judgment value.
Indicates information on the item in
(5)
Sub-display 2
the maximum/minimum/(maximum-
minimum)/input value monitoring mode.
Pressing the Enter and Mode keys
together changes to the parameter
setting mode.
Pressing the Enter and Increment keys
together changes to the maximum/
minimum/(maximum-minimum)/input
(6) Enter key
value monitoring mode.
Switches from the maximum/
minimum/(maximum-maximum/
minimum/(maximum-minimum)/input
value monitoring mode to the
comparative judgment reading mode.
Pressing the Mode and Enter keys
together changes to the parameter
setting mode.
Pressing the Mode and Shift keys
(7)
Mode key
together changes to the shift function
setup mode.
Pressing the Mode and Incremental
keys together turns on/off the "Digital
zero" indicator.
Pressing the Shift and Enter keys
together changes to the parameter
checking mode. (Comparator data can
be set.)
Pressing the Shift and Mode keys
(8) Shift key
together changes to the shift function
setup mode.
Selects from items in the maximum/
minimum/(maximum-minimum)/input
value monitoring mode. (Hold down the
key for about one second.)
Pressing the Increment and Mode keys
together turns on/off the "Digital
zero" indicator.
Pressing the Increment and Enter keys
changes to the maximum/minimum/
(9)
Increment key
(maximum-minimum)/input value
monitoring mode.
Resets the maximum/minimum/
(maximum-minimum)/input value
monitoring mode. (Hold down the key
for about one second.)
(8)
(9)
Main Functions
During measurement
IIndicates information on the
parameter to be set.
Indicates the item to be set.
Returns to the measurement
mode.
Selects the item to be set.
Changes the digit to be set.
Changes the value or content
of a selected digit.
(Increments the value)
(4)
(5)
(3)
During parameter setup

Advertisement

Table of Contents
loading

Table of Contents