BFT GIUNO ULTRA BT A20 Installation Manual
BFT GIUNO ULTRA BT A20 Installation Manual

BFT GIUNO ULTRA BT A20 Installation Manual

Piston automations for swing gates
Hide thumbs Also See for GIUNO ULTRA BT A20:

Advertisement

Quick Links

PISTON AUTOMATIONS FOR SWING GATES
Caution! Read "Warnings" inside carefully!

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GIUNO ULTRA BT A20 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for BFT GIUNO ULTRA BT A20

  • Page 1 PISTON AUTOMATIONS FOR SWING GATES Caution! Read “Warnings” inside carefully!
  • Page 2 USER GUIDE:EMERGENCY OPERATION- ACTIVATING EMERGENCY RELEASE. FIG.1 Locking open + locking closed Non-locking GIUNO ULTRA BT A20 - GIUNO ULTRA BT A50...
  • Page 3: Quick Installation

    Before commencing installation, make sure you read the warnings. b) In addition to the figures, you must follow the instructions given in the CABLE ARRANGEMENT PILLAR FASTENINGS INSTALLATION DISTANCES. GIUNO ULTRA BT A20 GIUNO ULTRA BT A50 Tables refer to an 80mm-thick gate. INSTALLATION DIAGRAM. α° GIUNO ULTRA BT A20 - GIUNO ULTRA BT A50 -...
  • Page 4 POWER CABLE. 30 mm H07RN-F 4x2.5mm -REF SWE Wire before installation ATTACHING MOTOR TO FASTENING ON PILLAR. GIUNO ULTRA BT A20 GIUNO ULTRA BT A50 44,5 63,5 54,5 29,5 Ø12 Ø12 GIUNO ULTRA BT A20 - GIUNO ULTRA BT A50...
  • Page 5: Maximum Tilt

    MAXIMUM TILT BT A20 L1 L2 BT A50 CORRECT INSTALLATION CLOSE GIUNO ULTRA BT A20 307 mm MAX OPEN CLOSE GIUNO ULTRA BT A50 455 mm MAX OPEN Ø5 GIUNO ULTRA BT A20 - GIUNO ULTRA BT A50 -...
  • Page 6 Not provided! CLOSING LIMIT DEVICE ADJUSTMENT LED ON with sensor activted CLOSE Closing limit stop Closing slow-down OPENING LIMIT DEVICE ADJUSTMENT ON with sensor activted OPEN Opening limit stop Opening slow-down GIUNO ULTRA BT A20 - GIUNO ULTRA BT A50...
  • Page 7: Locking Settings

    IF NECESSARY. Attention!! Turn SLOWLY until you hear (and can touch) the mechanical stop inside mechanism!!! Locking open NO locking open, Locking closed, NO locking closed Locking open + locking closed Non-locking, GIUNO ULTRA BT A20 - GIUNO ULTRA BT A50 -...
  • Page 8 COVER POSITIONING. Left 3,5 1 Ø 5,8 Ø 8.5 Right Careful not to damage the limit switch wires BT A20 776 268 1108 BT A50 883 390 1347 GIUNO ULTRA BT A20 - GIUNO ULTRA BT A50...
  • Page 9 Left Right Ø5 Ø5 Rod all the way in max 3 Nm Ø1 Ø6 GIUNO ULTRA BT A20 - GIUNO ULTRA BT A50 -...
  • Page 10: General Information

    1) GENERAL INFORMATION Correct installation entails maintaining a rod stroke margin of approx. 10mm on Compact and strong hydraulic piston, available in the GIUNO ULTRA BT A20 and the maximum stroke to avoid possible trouble with operation. GIUNO ULTRA BT A50 versions.