Word
Byte 0
Byte 1
Byte 2
MPX
MTO
MTI
MBI
0 Operational-out
0 Operational-in
B
1 Select-out
Address-in
u
2 Address-out
*2 Status-in signal
s
3 Command-out
*3 Service-in signal
4 Service-out
4 Select-in
l
5 Interrupt
5 MPX-request in
N
6 Suppress-out
6 MPX or Cons Req In
7 MPX check
7 Discon nect·i n
Note:
*Bits 2-3
Bits 2 and 3 of MTI are logical functions
of the interface 'service-in' and 'status-in'
lines.
00 =Op-in up
01 = Service-in up
10 =Status-in up
Byte3
MBO
B
u
s
0
u
T
11
= Operational-in down
TERMINATOR PART NUMBERS
System/360
System/370
Bus -
TAG-
5440649 2282675
5440650 2282676
Interface
SOSO
Asm
MPX CHANNEL DATA FLOW
II
4.1