Commands
Hex Code
Command
Single
Multi-
Type
Command Name
Track
Track
Control
Seek (BB CC HH)
07
-
Seek Cylinder (CC HH)
OB
-
Seek Head (HH)
1B
-
Recalibrate
13
-
No Operation
03
-
Set File Mask
1F
-
Space Count
OF
-
Restore (2321 only)
17
-
Sense
Test
1/0
00
-
Sense
1/0
04
-
Read
Read Data
06
86
Read Key-Data
OE
8E
Read-Count-Key-Data
1E
9E
Read Home Address
1A
9A
Read RO
16
96
Read Count
12
92
Read IPL
02
-
Write
Write Data
05
-
Write Key-Data
OD
-
Write-Count-Key-Data
1D
-
Write Home Address
19
-
Write RO
15
-
Write (Special)
01
-
Count-Key-Data
Erase
11
-
Search
Search Equal ID
31
B1
Search High ID
51
D1
Search Equal-Hi-ID
71
F1
Search Equal Key
29
A9
Search High Key
49
C9
Search Equal-Hi Key
69
E9
i
Search Equal HA
39
B9
Search Equal Key Data
2D
AD
Search High Key Data
4D
CD
Search Hi-Eq Key Data
6D
ED
Continue Scan Equal
25
A5
Continue Scan High
45
C5
Continue Scan Hi Eq
65
E5
Continue Scan,
55
D5
No Compare
Continue Scan,
75,35
F5,B5
Set Compare
Seek Address
Cell Number Cylinder Number Head Number
Type ByteO Byte1 Byte2 Byte 3
Byte
4
Byte
5
2314
0
0
0
0-202
0
0-19
File Protection
The significance of the file mask bits is:
BO B1
0
0
0
1
1
0
B3 B4
0
0
0
1
1
0
1
1
Inhibit Write Home Address and Write RO
Inhibit all write commands
Inhibit Write Home Address - Inhibit Write RO -
Inhibit Write Count, Key, and Data
Permit all write commands
Permit all seek and restore commands
Permit Seek CCHH and HH CCWs
Permit Seek HH CCW
Inhibit all seek commands
B2 B5 B6 B7
0
0
0
0
Status Byte
Bit
Name
Note
0
Attention
Not Used
1
Status Modifier Used with Search and Control
Unit Busy.
2
Control Unit
The control unit has finished
End
an operation.
3
Busy
Indicates addressed access
mechanism is moving; or used in
conjunction with Status Modifier
to indicate Control Unit Busy.
4
Channel End
The control unit has received all
the data from the channel needed
to do the operation called for
and the channel is freed.
5
Device End
Indicates that an access mechanism
is free to be used.
6
Unit Check
Indicates that a control unit or
programming error or device
hardware check has been
detected.
7
Unit Exception End-of-File.
CONTROL WORDS FORCED FOR IFA
SHARE CYCLE
Output
Input
Skip
MS
60680C08
68880C08
68840E08
cs
60884008
68884008
68844208
NOTE: These control words are hardware
forced into the C-reg.
IFACLOCK
~---400nsec--------
300
Bot
Ring Adv
(Only on Bit Ring 7)
5.4