Download Print this page

IBM System/370 145 Reference Summary page 100

Hide thumbs Also See for System/370 145:

Advertisement

MPX CHANNEL MACHINE DEPENDENT LOG
CS Build
MPX Channel M9ch1n1 Dependent Log
Area BFOO
Or111mal
WordNh1
ByteO
Byte 1
Byt12
Byte3
Loc111on
MA
Note 1
J_
UrntAddr
UCWAddress
LS 18
Int Buffer
MBS
ADDA
Status
SaqNo.
LS 19
MC
.
..,
Next CCW Addr
LS 18
MC KAO
MCKA1
MCKA2
MCKA3
EXT07
MCKB
MCKBO
MCKB1
MCK82
MCKB3
EXT06
MPX
MPX
MTO
MTI
MBI
MBO
EXT OE
ooc
Tl
TA
TT
TE
EXT OF
MO
Catalog No.
I.SIC
MF
Flags, Ops
~.f.X"t5~AN
Count
LS IO
BF24
~are
FB04
Reny Courits
Note2
CS FF84
FB10
ABRTY
ABRTY1
ABRTY2
ABRTY3
EXT 18
I
SPTLB
DATY
TRTY
LRTY
EXT 19
HMRTY
MRTY2
MRTY3
EXT 1A
CPURTY
BYTDST
RTYFLG
LS OST
EXTOST
EXT 18
Control Word
(Control
ord
in
Error)
SYS REG
SYSO
SYS1
SYS2
H-REG
EXT05
I REG
KEY REG
Instruction Counter
EXP LS50
F82C
U REG
ILCICC
::~s°t
IAMWP
Op Code
lmmed Byte EXP LS 53
(Spare)
!Spare)
!Spare)
(Spare)
!Spare)
Note 1
MA-REG
Byte 0
811 0
~
1 MPX Log Valid
8110~0
MPXLoglnvaltd
Ratrv Counts
ByteO
Bits0-3
Zero
B1ts 4-7
Retry Attempts for Current Instruction
Byte 1 and 2 Zeros
Byte 3
Number of Instructions Retried
Stop after 1/0 Log Start Address
Catalog Numbers (IFCC Only)
M1 - No-Op-in time out
M2 - Status-in ttme-Qut
M3 - No-address-in time-out
M4 - Address m bad parity/no address match
M5 - No-status-in time-out
M6 - Op-in t1me-Qut
M7 - Bad parity status-in
Catalog number byte/bit srgmf1cance
M"
Primary number
01234567
Ll -
Share trap
1 - Chammg
~
M - 0 - I mt1al
sel~t•on
or burst mode
M8 - Time-out in data loop, inbound
tag
sequence bad
Op in failed to fall
M9 -Disconnect-in
b NoSVCorSTAs1gnat
MA - Bad parity on status
c
Both inbound tags up
MB - Service-in - eKpected status-in
lC
"'False share request from doc-console
- Select-in during chaining
SELECTOR CHANNEL/BLOCK MULTIPLEX
CHANNEL DEPENDENT LOG
CS
Build
Area BFOO
BF24
FB04
F810
I
F82C
.---
-
- -
WordN1tme
GBS
GSTAT
GTAG
MCKA
MCKB
GDRL
GD
GC
GW
Retry Counts
ABRTY
SPTLB
HMRTY
CPURTY
Control Word
SYS REG
l
REG
U REG
(Spare)
(Spare)
(Spare)
(Spa rel
(Spare)
GBS
Note2
Selector Channel /Block Multiplex Channel Dependent Log
ByteO
Byte
1
Byte
2
Byte3
Log Length
GBF
GCT
GBO
Note
1
GE
GS
GL
GTO
GTI
GO
GR
MCKAO
MCKA1
MCKA2
MCKA3
MCKB1
MCKB2
MCKB3
CHANNEL WORKING REGISTERS
CHANNEL WORKING REGISTERS
CHANNEL WORKING REGISTERS
:I
Cata!ogN..'1
Note 2
ABRTYO
ABRTY1
ABRTY2
ABRTY3
SRTY
PRTY
TRTY
HRTY
MRTY2
BYTDST
RTYFLG
LS DST
EXTDST
iControl Word
m
Error)
SYSO
SYS
1
SYS2
I
nstruct1on Counter
KEY REG
=r
1Lc:cc:~~M
: AMWP
Op-Code
_l
1mmed Byte
Only when log is rn ms
Byte 0
~
28 Only SX Log
Valid
Byte0~4C
SXandCPULogValid
Ong mill
Location
EXT 31 (SX2J
EXT 32 (SX2)
EXT 33 ISX2)
LS20 1SX21
LS21 (SX2)
LS22 (SX2)
LS23 tsX2)
EXT
18
EXT
19
EXT 1B
EXP LS
50
EXP LS 53
Retry Counts
ByteO
B1ts0.3
Zero
B1ts4-7
Retry Attempts for Current lnstruct1or.
Bytes 1 and 2
Zeros
Byte 3
Number of Instructions Retried
Catalog Numbers
00 - Indeterminate
01 - Automatic Selection Failed
02 - Halt Stop Will Not
Set
03 - Microcode Select Failed on Halt
04 - Interface Disconnect Failed
05 - Selective Reset Failed
06 - Address Check on Channel-Initiated Selection
07 - Short Busy on Cha1nmg
08 - Poll Control will not set (soft)
09 - Address Parity Error on Ctrl Unit Initial Setectmn
OA- Disconnect-In Received
OB - Hard Set of Poll Control Failed
OC- Unused
OD- Unseccessful Microprogram Retry
OE - Select-In on Chammg
OF - Status·ln Parity Error
I
1
ceu
IFA EXTENDED LOGOUT
IFA Extended Logout
Word Name
ByteO
Byte 1
Byte
2
ByteJ
FBAK
Log Length
FCH
FCL
FOP
Note
1
FSTAT
FFL
FCS
FST
FGL
FTAG
FTO
FTI
FBO
FDR
MCKA
MC KAO
MCKA1
MCKA2
MCKA3
MCKB
MCKBO
MCKBl
MCKB2
MCKB3
FOAL
FD
Protect
Data Address
FC
Count
FM
Protect
CCW Address
FW
Urnt Address
AetryCounts
Note2
ABRTY
ABRTYO
ABRTY_i
ABRTY2
ABRTY3
SPTLB
SRTY
PRTY
:I
TRTY
_J
LATY
HMRTY
HRTY
:r
MRTY2 __[ MRTY3
CPURTY
BYTDST
RTYFLG
LS DST
EXTDST
Control Word
{Control Word
In
Error)
SYS REG
SYSO
SYS1
SYS2
_l
H-REG
I REG
KEY REG
Instruction Counter
U REG
!LC
:cc
l~~sgk
: AMWP : Op Code
lmmed Byte
(Spare)
(Spare)
(Spare)
(Spare)
(Spare)
Note 1
FBAK
Byte 0 - 28 Only lFA Log Valid
Byte 0
=
4C 1FA and CPU Log Valld
Note 2
Retry Counts
ByteO
Bits 0-3
Zero
Bits 4-7
Retry Attempts for Current l nstruction
Bytes l and 2 Zeros
Byte 3
Number of Instructions Retried
8:10
Or1gmal
Location
EXT
20
EXT 22
EXT 23
EXT 07
EXT 06
IFA
LS28
l
LS29
LS2A
LS28
EXT 18
EXT 19
EXT 1A
EXT 18
I
EXT 05
EXP LS 50
EXPLS53

Advertisement

loading