Introduction
AC12 Technical Specifications
Power Consumption
Power Input
Inputs
Readers
PoE Output
Relay Outputs
DC Power Output
Dimensions
Weight
Tamper Detection
Operating Temperature
Compliance
Connectivity
Included Accessories
Mounting Options
4
60W maximum
IEEE 802.3af/at/bt PoE, PoE+, PoE++ (37VDC — 57VDC), 600mA maximum
per pair; 12VDC with 2.5A minimum current
2x REX dry inputs
1x DPI dry input
1x AUX dry input
2x 12VDC @ 250mA reader ports (Verkada/RS-485 or Wiegand)
Note: Each of the 2 reader ports can power a maximum of 1 reader with
current consumption of at most 250mA.
IEEE 802.3af/at PoE, PoE+ (37VDC–57VDC), 600mA maximum
1x wet relay for door with switch-selectable power:
● 12VDC operation @ 700mA maximum
● 24VDC operation @ 350mA maximum
● Dry operation
1x dry relay for auxiliary output with maximum pass-through power of
24VDC @ 2A (resistive load)
1x 12VDC @ 100mA maximum
175.5 x 175.4 x 55.3 mm (6.91 x 6.91 x 2.18 in)
2.87 lb (1.30 kg)
Yes
0 °C-50°C, 5-85% humidity
FCC Part 15B Class B, ICES-003 Class B, CE, UKCA, VCCI, RCM, UL 294,
CAN-ULC 60839-11-1, UL 62368-1, and CSA C22.2 No. 62368-1, IK06,
Compliant with Requirements of UL2043, Indoor Use Only, to be used in
controlled, protected, and/or restricted access areas
Installation and operation of the electronic access control system (EACS)
shall not prevent the functionality of the emergency exit functions.
Ethernet: 10/100/1000 Mbps RJ-45 for network connection
USB 2.0
T10 Security Torx screwdriver, mounting hardware kit
Wall, Ceiling, or Plenum Mount