This equipment is for use in a restricted access area. Warning Ensure power is disconnected from AX11 while servicing the product or connecting/disconnecting peripherals. Document revision V1.0 Levels of Access Control •...
M4 screw. Required Network Settings An Ethernet connection with DHCP must be used to connect the AX11 to the Local Area Network (LAN). You also need to configure firewall settings to communicate with the AX11. • TCP port 443 •...
Relay Outputs AX11 comes equipped with a Form C relay that can be driven dry. Max DC load: 24V @ 1A, Max DC current = 1A, Max DC voltage = 60VDC. Verkada Inc. 405 E 4th Ave, San Mateo, CA, 94401 All specifications are subject to change without notice.
When connecting to an elevator system, it is recommended to wire in a fail safe configuration. Each button’s signal wire should be connected in series with the NC and COM terminal of an AX11 relay output. Wiring a Powered Lock It is recommended to interface with an Access Power Controller to provide power to the accessory.
Page 10
Wiring a Verkada or Wiegand Reader The AX11 is rated to power readers at 12V up to 250mA via the + Vin and - GND connection. The drain wire of the shielded cable should be secured to nearest AX11 grounding point.