M-system R80ND2 Operating Manual

Power/network module

Advertisement

Quick Links

OPERATING MANUAL
POWER/NETWORK MODULE
BEFORE USE .... ........................................................................................................... 2
POINTS OF CAUTION ...................................................................................................... 2
INSTALLATION ............................................................................................................. 2
COMPONENT IDENTIFICATION .......................................................................................... 3
TERMINAL CONNECTIONS ............................................................................................... 5
WIRING INSTRUCTIONS .................................................................................................. 6
DeviceNet I/O ASSIGNMENTS ........................................................................................... 7
STATUS...................................................................................................................... 9
I/O DATA DESCRIPTIONS ............................................................................................... 10
(DeviceNet
)
®
CONTENTS
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
R80ND2
MODEL
EM-7035-B P. 1 / 10

Advertisement

Table of Contents
loading

Summary of Contents for M-system R80ND2

  • Page 1: Table Of Contents

    COMPONENT IDENTIFICATION ..................3 TERMINAL CONNECTIONS ....................5 WIRING INSTRUCTIONS ....................6 DeviceNet I/O ASSIGNMENTS ................... 7 STATUS........................9 I/O DATA DESCRIPTIONS ....................10 EM-7035-B P. 1 / 10 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp...
  • Page 2: Before Use

    • Indoor use. • When heavy dust or metal particles are present in the Thank you for choosing M-System. Before use, please check air, install the unit inside proper housing with sufficient contents of the package you received as outlined below.
  • Page 3: Component Identification

    (Factory setting: 00) Node Address Setting (x10) Node Address Setting (x1) EM-7035-B P. 3 / 10 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp...
  • Page 4 FUNCTION   No.   1  V‑  POWER (‒)   2  CAN̲L  Signal Low   3  Drain  Shield   4  CAN̲H  Signal High   5  V+  POWER (+) EM-7035-B P. 4 / 10 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp...
  • Page 5: Terminal Connections

    ■ EXTERNAL DIMENSIONS unit: mm [inch] • Unit 50 [1.97] (3 [.12]) 73 [2.87] (4 [.16]) DIN rail (35mm wide) • PROTECTIVE COVER 5 (.20) 50 (1.97) EM-7035-B P. 5 / 10 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp...
  • Page 6: Wiring Instructions

    AI0,5-10WH 0.5 mm (Phoenix Contact) AI0,75-10GY 0.75 mm (Phoenix Contact) AI1-10RD 1.0 mm (Phoenix Contact) AI1,5-10BK 1.5 mm (Phoenix Contact) AI2,5-10BU 2.5 mm (Phoenix Contact) EM-7035-B P. 6 / 10 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp...
  • Page 7: Devicenet I/O Assignments

    I/O module. If the I/O module is an input type, input data is assigned in order from the 3rd word of IN area (R80ND2 to master device). If the I/O module is an output type, output data is assigned in order from the beginning of OUT area (master device to R80ND2).
  • Page 8 ■ EDS FILE EDS files are downloadable at M-System’s web site. R80ND2 automatically determines IN/OUT area size of DeviceNet when the power is turned on according to the configuration of the connected I/O module. Only the largest data size is registered on the EDS files. When registering to the master device, set the data size according to the configuration of I/O modules.
  • Page 9: Status

    1: Some I/O modules are out of input range, or in burnout 0: Input of all I/O modules are normal Status 2 bit0 to 15 (reserved) EM-7035-B P. 9 / 10 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp...
  • Page 10: I/O Data Descriptions

    ■ DISCRETE DATA (models: R80DAT16A2, R80DCT16A2, R80DCT4D, etc.) Input 1 (Output 1) Input 2 (Output 2) Input 3 (Output 3) Input 16 (Output 16) 0 : OFF 1 : ON EM-7035-B P. 10 / 10 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp...