Trouble Shooting - TCL TAC-09CSD/XAB1 Service Manual

Table of Contents

Advertisement

 

3.2 Trouble shooting

3.2.1 E1, E2 ---IDU Room temperature sensor and/or coil temperature sensor failure.
 
 
TCL Air Conditioner Service Manual 
Start
Display E1or E2
Is the sensor well
connected to PCB
Yes
Multi-meter check the
sensor, is it open or
short circuit?
Yes
Replace IDU PCB
End
No
Re-connect
E1/E2
disappear?
No
No
Replace the sensor
The malfunction
eliminated?
No
Yes
Yes
32

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tac-12csd/xab1Tac-18csd/xab1

Table of Contents