Daikin Altherma 3 H HT ECH2O Service Manual page 324

Hide thumbs Also See for Altherma 3 H HT ECH2O:
Table of Contents

Advertisement

4
|
Components
Service manual
324
Name
Symbol Location
Outlet water
R10T
after plate
type heat
exchanger
thermistor
4 Determine the thermistor resistance that matches the measured
temperature.
Thermistor – Table A
T °C
T °C
–20
197.81
10
–19
186.53
11
–18
175.97
12
–17
166.07
13
–16
156.80
14
–15
148.10
15
–14
139.94
16
–13
132.28
17
–12
125.09
18
–11
118.34
19
–10
111.99
20
Connector
(PCB)
(pins)
A4P (O/U)
X12A: 1‑2 –
T °C
39.96
40
38.08
41
36.30
42
34.62
43
33.02
44
31.50
45
30.06
46
28.70
47
27.41
48
26.18
49
25.01
50
Inter-
Reference
mediate
(table)
connector
(pins)
A
T °C
10.63
70
3.44
10.21
71
3.32
9.81
72
3.21
9.42
73
3.11
9.06
74
3.01
8.71
75
2.91
8.37
76
2.82
8.05
77
2.72
7.75
78
2.64
7.46
79
2.55
7.18
80
2.47
EPRA14~18D + ETSH/X(B)16P30+50E