MANUAL WOOD BOILER STOVE Table of contents Introduction ................................4 The boiler stove ............................... 4 Combination with solar collectors or a heat pump ....................4 Technical data ................................5 Assembly ................................. 8 Delivery of the stove ............................8 The right setup location ............................8 Connection to the flue pipe ............................
Page 3
MANUAL WOOD BOILER STOVE Cleaning the fireplace and flue system ......................21 Mounting glass pane ............................21 Door closure ..............................21 Vermiculite or chamotte stone ........................21 Warranty conditions ............................... 22 Deviations ................................23 Service and faults .............................. 23...
If you have any questions or problems while using the device, refer to this manual for help. If you still encounter problems, contact your supplier for further support. Nordic Fire wishes you much heating pleasure! The boiler stove A boiler wood stove is an advanced type of wood stove that not only provides warmth and ambience, but is also used to provide hot water to a central heating system in your home.
Ensure that the installation location is chosen to allow a straight connection to the chimney. The exact requirements will be specified by your installer or Nordic Fire dealer. Nordic Fire's boiler wood stoves are usually fitted with a top connection. A rear connection is not possible.
Important when connecting tot he chimney: The chimney must be checked in advance by the Nordic Fire installer for leaks and the condition of the chimney. A brickwork, uninsulated flue is not allowed! A masonry flue must be lined with a suitable inner pipe which is insulated.
MANUAL WOOD BOILER STOVE CAUTION: A boiler wood stove with a high efficiency (read: high resistance) is susceptible to an improperly functioning chimney. We recommend using a fully insulated duct with a diameter of at least the connection of the stove. A larger diameter will improve draught and is therefore advisable.
The guarantee on the boiler wood stove is only applicable if it has been installed by the Nordic Fire dealer - installer. They should observe this manual as well as the applicable legal regulations. Annually, the cooling coil should be checked for leaks.
MANUAL WOOD BOILER STOVE The technology Thermal safety (temperature protection) In the Netherlands, it is compulsory for a boiler wood stove to be fitted with a cooling coil, which is integrated in the heat exchanger. This cooling coil must be fitted with a temperature safety device 95 degrees.
MANUAL WOOD BOILER STOVE Filling and bleeding Proper venting of the central heating system is necessary to ensure proper operation of the boiler wood stove. Make sure there are sufficient vents at high points at branch points. Venting the system is often problematic and can take a long time.
MANUAL WOOD BOILER STOVE Commissioning Important to know: A central heating wood stove should never be used if it is not connected to the central heating system. High temperatures can damage the heat exchanger. In case of prolonged power failure, one should not refill wood and stop firing. When installing the central heating wood stove and connections, follow the applicable guidelines.
MANUAL WOOD BOILER STOVE Heating capacity of the stove The actual output of the stove is largely determined by the amount of wood fired. As a rule of thumb: 1 kg of wood corresponds to 3 kW of power. The capacity of the stove is indicated on the rating plate. This is the output that is achieved with the prescribed amount of wood during inspection.
MANUAL WOOD BOILER STOVE Nuisance and environment Wood firing is a natural process that releases as much CO2 as during decay in the forest. However, poor combustion can release harmful fumes. That is why it is imperative that you, the user, fire correctly to avoid nuisance.
Wood as a fuel Only wood that is sufficiently dry, cleaved and clean is suitable for use in a Nordic Fire wood stove. Do not use wet wood. This is wasted energy (50% less energy!) and it pollutes your stove AND chimney, increasing the risk of chimney fire.
MANUAL WOOD BOILER STOVE A few tips Wood should be stored split. Firewood should be stored in a windy place, protected from rain. Hardwood should dry longer than lighter woods Damp wood is wasted energy. It pollutes your chimney and causes nuisance in the surrounding area.
Cleaning the glass window The Nordic Fire boiler wood stove is constructed so that the secondary air supply ensures that the glass pane is cleaned. Due to the high temperature and this air supply, dirt particles are burned as much as possible.
Any freight costs will be at your expense. If the fault on the appliance is of such a nature that the installer cannot rectify it, then Nordic Fire bv is only prepared to take care of this at the request of the installer.
Service and faults Despite all the care taken in the production of Nordic Fire fireplaces, it may happen that something is not right. In that case, contact your dealer or installer. In most cases, your dealer or installer will solve the problem immediately.