THE MACHINE AND THE PELLETS ..........................4 ................................4 OMPONENTS OF THE APPLIANCE HRV VIKTOR..............................7 VERALL DIMENSIONS FOR HRV TORSBY..~ ............................8 VERALL DIMENSIONS FOR HRV VIKTOR............................9 ONNECTIONS DATA SHEET FOR HRV TORSBY............................10 ONNECTIONS DATA SHEET FOR ..................................11 ECHNICAL PECIFICATIONS ....................................
Page 4
EN - Rev. 1.0 Dear client, First of all we would like to thank you for choosing a “NORDIC FIRE” product and we hope you will be satisfied with this product. Carefully read the manual and warranty certificate on the last page of this User guide.
PELLET BOILER STOVE HRV VIKTOR / HRV TORSBY EN - Rev. 1.0 INTRODUCTION Important safety instructions Please read these instructions before installing and using the product. - The installation and initial start-up of the appliance must be performed by skilled personnel trained in the relevant safety standards.
- This user guide constitutes an integral part of the appliance. If the product is sold to another user, this manual must be passed on to the new owner. Nordic Fire BV DECLINES ALL LIABILITY IN CASE OF ACCIDENTS DUE TO FAILURE TO COMPLY WITH THE SPECIFICATIONS OF THIS MANUAL.
Page 7
PELLET BOILER STOVE HRV VIKTOR / HRV TORSBY EN - Rev. 1.0 The images below show certain details of the appliance: Hook for cleaning the front heat exchanger. REAR VIEW CE label Opening with technical data, serial for optional connection to number and model.
Page 8
PELLET BOILER STOVE HRV VIKTOR / HRV TORSBY EN - Rev. 1.0 LEFT SIDE VIEW Pellet tank. Front fan for hot air. Flue gas intake device. Overpressure valve. Flue pressure switch. RIGHT SIDE VIEW Safety valve (2.5 bar). Automatic air vent valve (jolly).
Page 9
PELLET BOILER STOVE HRV VIKTOR / HRV TORSBY EN - Rev. 1.0 Overall dimensions for HRV VIKTOR...
PELLET BOILER STOVE HRV VIKTOR / HRV TORSBY EN - Rev. 1.0 Overall dimensions for HRV TORSBY...
Page 11
PELLET BOILER STOVE HRV VIKTOR / HRV TORSBY EN - Rev. 1.0 Connections data sheet for HRV VIKTOR REAR VIEW Description of connections M = System Delivery 3/4" M R = System Return 3/4" M X = Safety valve drain 1/2"...
Page 12
PELLET BOILER STOVE HRV VIKTOR / HRV TORSBY EN - Rev. 1.0 Connections data sheet for HRV TORSBY REAR VIEW Description of connections M = System Delivery 3/4" M R = System Return 3/4" M X = Safety valve drain 1/2"...
/ Nummer Leistungserklärung / C-613 Numéro déclaration des performances Unique identification product-type / Uniek identificatiecode producttype / HRV Viktor Eindeutiger Kenncode de Produckttyp / Code d'identification unique du produit typ Type, batch or serialnr. / Type-, partij- of serienummer / Typen-, HVTR Chargen- oder Seriennummer / Numéro de type, de lot ou de sèrie...
Haushalten mit Holzpellets / Appareil de chauffage domestique alimenté au granulés de bois Contact address of the manufacturer / Contactadres van de fabrikant / Nordic Fire B.V. Kontaktadresse des Herstellers / Adresse de contact du fabricant De Immenhorst 5 7041 KE 's Heerenberg...
PELLET BOILER STOVE HRV VIKTOR / HRV TORSBY EN - Rev. 1.0 Pellet properties The appliance has been tested with all types of pellets available on the market. The pellets must have the following properties: - Diameter 6 mm. - Maximum length 35 mm.
PELLET BOILER STOVE HRV VIKTOR / HRV TORSBY EN - Rev. 1.0 The unit must be installed on a floor with a suitable load capacity. If the existing building does not fulfil this requirement appropriate measures (e.g. load distribution plate) must be taken.
PELLET BOILER STOVE HRV VIKTOR / HRV TORSBY EN - Rev. 1.0 If there are other heating or extraction devices inside the room, the air vents must guarantee a sufficient amount of air for properly operating all the devices. Only sealed appliances (e.g. C type gas appliances, according to the UNI 7129 Standard) or appliances that do not cause a lower pressure compared with the external environment can pre-exist or be installed in the place where the appliance is installed.
PELLET BOILER STOVE HRV VIKTOR / HRV TORSBY EN - Rev. 1.0 - It is forbidden to allow other air intake conduits and system pipes to transit inside the flue gas pipes, even if they are over-sized. FURTHER SPECIFICATIONS TO BE CONSIDERED - The appliance works with the combustion chamber in depression and the flue pipe in pressure;...
Do not pass electric cables in the immediate vicinity of the flue gas pipe, unless they are insulated with BV materials. Nordic Fire BV declines all responsibility for injury to persons and animals or damage to objects due to failure to connect the appliance to earth or to comply with IEC specifications.
PELLET BOILER STOVE HRV VIKTOR / HRV TORSBY EN - Rev. 1.0 BROWN COUPLED BOILER PUMP R.T. CONTACT BLUE Control of a possible three-way motorized valve for DHW system management The pellet appliance is equipped as standard with a control for a possible 3-way motorised valve to be installed on the domestic water circuit based on the selected system type (see “System...
PELLET BOILER STOVE HRV VIKTOR / HRV TORSBY EN - Rev. 1.0 HYDRAULIC CONNECTION The plumbing connections must be made in a rational way using the connections on the template of the appliance. The appliance can be coupled with any other boiler already installed on the system. In this case it is essential to fit all the necessary safety devices and shut-off valves based on the system and intended use.
PELLET BOILER STOVE HRV VIKTOR / HRV TORSBY EN - Rev. 1.0 THE DISPLAY The appliance's operating mode is displayed on the console. After turning on the menu, it is possible to choose from many types of display and available settings according to the selected menu.
Page 26
PELLET BOILER STOVE HRV VIKTOR / HRV TORSBY EN - Rev. 1.0 The meanings of the status signals appearing on the top right side of the display are described below (2nd LED SERIES). - LED 1: the LED lights up when the daily programme of the on off settings is active.
PELLET BOILER STOVE HRV VIKTOR / HRV TORSBY EN - Rev. 1.0 Switches the appliance on and/or off when pressed for Working.. 2 seconds. ON/OFF In alarm block.. Releases the alarm. Outlet Menu/programming Moves you to the previous menu level, saving the mode..
Page 28
PELLET BOILER STOVE HRV VIKTOR / HRV TORSBY EN - Rev. 1.0 MENU LEVEL SELECTION MEANING POSSIBLE VALUES 03 – 01 – 01 ACTIVATE TIMER Enable/disable set programs ON – OFF Submenu 03 – 02 – daily program Allows you to enable, disable and set the programmable thermostat daily programme functions.
Page 29
PELLET BOILER STOVE HRV VIKTOR / HRV TORSBY EN - Rev. 1.0 PROGRAMME 3 MENU LEVEL SELECTION MEANING POSSIBLE VALUES 03 – 03 – 20 START PROG 3 Turn-on time of the third programme Time – OFF 03 – 03 – 21...
Page 30
By reducing the value by a single unit, the flue gas extractor speed (and therefore the flow of combustion air) is reduced by about 3%. * Unauthorised access can cause serious damage to equipment, objects and the environment, as well as personal injuries. Nordic Fire declines all responsibility deriving from improper calibration of these values.
PELLET BOILER STOVE HRV VIKTOR / HRV TORSBY EN - Rev. 1.0 INITIAL START-UP System configuration Before commissioning the appliance it is advisable to choose which type of system it has been connected to, by accessing “Menu 06 – System type”.
Page 32
PELLET BOILER STOVE HRV VIKTOR / HRV TORSBY EN - Rev. 1.0 T.A. Bollitore cylinder accumulo Plumbing layout 3 involves connecting the boiler stove to a heating system managed by one or more room thermostats. These are connected to the terminal located inside the appliance’s left technical compartment. DHW will be generated by means of a hot water cylinder fitted outside of the boiler and controlled by a temperature probe connected to the appliance.
PELLET BOILER STOVE HRV VIKTOR / HRV TORSBY EN - Rev. 1.0 Plumbing layout 4 involves connecting the boiler to a centralised puffer controlled by a temperature probe connected to the appliance. The boiler stove will therefore operate only at the set temperature of the centralised puffer (“SET PUFFER”...
PELLET BOILER STOVE HRV VIKTOR / HRV TORSBY EN - Rev. 1.0 The ignition cycle can last 20/25 minutes max. and is divided into five steps: Step 1 - START = Flue gas intake device switches on and automatic brazier cleaning.
PELLET BOILER STOVE HRV VIKTOR / HRV TORSBY EN - Rev. 1.0 After setting the desired value, press button 4 or wait a few seconds to confirm. During the working mode the appliance enters “Economy mode operation” when that temperature value is reached.
PELLET BOILER STOVE HRV VIKTOR / HRV TORSBY EN - Rev. 1.0 The air fan can be can be switched off (“OFF”), manually set to a speed value (of between 1 and 5), or set to automatic mode (“Auto”), in which case the fan speed is associated with the operating power value set under SET POWER.
PELLET BOILER STOVE HRV VIKTOR / HRV TORSBY EN - Rev. 1.0 ...lack of power (blackout) If a power blackout occurs for a shorter time than Pr48, when power is restored, the appliance will immediately re-start in the working mode (recovering the set working power).
PELLET BOILER STOVE HRV VIKTOR / HRV TORSBY EN - Rev. 1.0 CLEANING AND MAINTENANCE Precautions before cleaning Before carrying out any cleaning or maintenance operations, make sure that: - the appliance is off and has cooled down completely; - the ash is completely cold.
PELLET BOILER STOVE HRV VIKTOR / HRV TORSBY EN - Rev. 1.0 After having removed the upper collar for the brazier (Figure 3), thoroughly clean the bottom of the brazier to eliminate any residues (Figure 4). Use a suitable ash vacuum device to remove any ash deposited around the brazier...
Page 40
PELLET BOILER STOVE HRV VIKTOR / HRV TORSBY EN - Rev. 1.0 After removing the underlying front panel (Figure 7), remove the cover of the inspection port by loosening the two screws (Figure After removing the cover, vacuum the residues inside the inspected compartment (Figure After completing this operation, put the previously removed components back in place.
PELLET BOILER STOVE HRV VIKTOR / HRV TORSBY EN - Rev. 1.0 To ensure correct operation, it is necessary to remove the sawdust deposited on the bottom of the tank (Figure 10) least once every 30 days. The pellet tank must be emptied at the end of every season.
Page 42
PELLET BOILER STOVE HRV VIKTOR / HRV TORSBY EN - Rev. 1.0 Unscrew the four hex-headed screws, following the sequence given in the photo (Figure 13). Remove the upper cap, fully sliding out the internal scrapers upwards (Figure 14). Vacuum the ash residues from the flue gas turn and combustion chamber.
You must periodically check the seals because the latter guarantee the air- and water-tightness of the appliance and its good functioning; if they are worn or damaged you need to be replace them immediately by contacting a Nordic Fire Authorised technical assistance centre.
Nordic Fire BV so as not to impair the operation of the appliance. The company shall not be held liable for any damage caused by the incorrect entry of parameters.
Page 45
PELLET BOILER STOVE HRV VIKTOR / HRV TORSBY EN - Rev. 1.0 Parameters “DEFAULT SETTINGS” - Mod. HRV VIKTOR / HRV TORSBY (N01_230419) Database Parameter Menu level Description Display Measurement Value field Pr01 M08 – 6 – 01 Ignition cycle maximum time...
Sound The Nordic Fire pellet stoves are very quiet compared to other brands. However, parts in the pellet stove can cause noise. This is a normal phenomenon and can possibly be remedied by cleaning or greasing the engines during normal...
Page 48
Pellets that are not tested can contain too much dust or do not always contain the right types of wood, which can cause poor combustion or damage. Parameters may not be changed by the user. without consultation with the installer (or employees of Nordic Fire bv). The device must not be treated roughly or damaged.
Page 49
PELLET BOILER STOVE HRV VIKTOR / HRV TORSBY EN - Rev. 1.0...