ELECTRICAL CONNECTION

WARNING
Electrical Requirements
A 115 volt, 60 Hz, AC only 15 amp fused electrical supply is required. (A time
delay fuse or circuit breaker is recommended.) It is recommended that a separate
circuit, serving only this appliance, be provided.
•ELECTRICAL GROUND IS REQUIRED ON THIS APPLIANCE.
•DO NOT UNDER ANY CIRCUMSTANCES REMOVE THE POWER SUPPLY CORD
GROUND PLUG.
•DO NOT USE AN EXTENSION CORD
Recommended Grounding Methods
For your personal safety, this unit must be grounded. This appliance is equipped
with a 7' (2.1 m) power supply cord having a 3-prong grounding plug. To minimize possible shock hazard, the cord must be
plugged into a mating 3-prong grounding type wall receptacle grounded in accordance with the National Electrical Code and
local codes and ordinances. If the circuit does not have a grounding type receptacle, it is the responsibility and obligation of
the customer to exchange the existing receptacle in accordance with the National Electrical Code and applicable local codes
and ordinances. The third ground plug SHOULD NOT, under any circumstances, be cut or removed. All UL listed refrigerated
drawers are equipped with this type of plug.

FINAL PREPARATION

1. Some stainless steel parts may have a plastic protective wrap which must be peeled off. The interior of the unit should be
washed thoroughly with hot, soapy water, rinsed and wiped dry to remove film residue and any installation dust or debris
before being used. Solutions stronger than soap and water are rarely needed.
2. All stainless steel parts should be wiped with hot soapy water. If buildup occurs, do not use steel wool, abrasive cloths,
cleaners, or powders. If it is necessary to scrape stainless steel to remove encrusted materials, soak with hot, wet cloths to
loosen the material, then use a wood or nylon scraper. Do not use a metal knife, spatula, or any other metal tool to scrape
stainless steel; scratches are almost impossible to remove.
Failure to follow these instructions could result in fire or electrical
shock.

WIRING DIAGRAM

UNDERCOUNTER 24" W. REFRIGERATED DRAWER
ELECTRICAL SHOCK HAZARD
Power Supply
with 3-prong
grounding plug
8
Grounding type wall
receptacle
WARNING: ELECTRICAL
GROUNDING
INSTRUCTIONS
This appliance is equipped with a
three prong grounding plug for
your protection against shock
hazard and should be plugged
directly into a properly grounded
three prong receptacle. Do not
cut or remove the grounding
prong from this plug.