eevTe
Chengdu
7. Command
format
Command mode (Mode 2: MO = 0, M 1 = 1), the list of supported commands is as follows (when set, only 9600, 8N1
format is supported):
No.
Instruction format
Detailed description
)
Send CO + 5 byte working parameters in hexadecimal format, a total of 6 bytes and
CO+operating
)
1
must be sent continuously (save when power off)
parameter
Send three Cls in hexadecimal format. The module returns the saved parameters and
2
Cl1+Cl1+C1
must be sent continuously.
)
Send C2 + 5 bytes working parameter in hexadecimal format, a total of 6 bytes and
C2+operating
)
3
must be sent continuously(do not save when power off)
parameter
Send three C3s in hexadecimal format. The module returns version information and
4
C3+C3+C3
must be sent continuously.
7.1 Default parameters
Model
Factory default parameter value:
CO 00 00 19 2E 00
Module type
Frequency | Address
Channel
Air rate
Baud rate
Transmitting power
E49-400T20S
| 433MHz
| 0x0000
0x2E
2.4kbps
9600
20
7.2 Reading operating parameter
Instruction format
Detailed description
In the setting mode (MO = 0, M1 = 1), issue a command to the module
serial port (HEX format): C1 C1 Cl,
CI+C1+C1
The module will return the current configuration parameters,
such as: C0 00 00 18 20 00
7.3 Reading version number reading