Factory Default Parameters; Trunking Mode Use - Ebyte E610-433T S Series User Manual

433mhz 100mw/1w wireless high speed link module
Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co.,Ltd.

7.3 Factory default parameters

Model
Restore factory default parameters command.C0 00 09 00 00 00 40 00 2E 00 00 00
number
Module type
Frequency
E610-433T20
433MHz
S

8. Trunking mode use

No
After setting the trunking mode via the configuration mode, switch to the general mode and the trunking
1
starts working.
The ADDH and ADDL are no longer used as module addresses in relay mode, but correspond to the
2
NETID to forward the pairing respectively, and if one of these networks is received, it is forwarded to the
other; the repeater's own network ID is invalid.
In relay mode, the relay module cannot send and receive data and is unable to perform low-power
3
operations.
The module resets the user parameters from mode 3 (sleep mode) to other modes or during a reset,
4
during which the AUX output goes low。
Trunking networking rules are described as follows.
1、Forwarding rules, trunking can forward data in both directions between two NETIDs.
2. In relay mode, ADDH\ADDL is no longer used as a module address and is forwarded as a NETID pair.
As shown in the diagram.
① Level 1 trunk
"Node 1" NETID is 08.
"Node 2" NETID is 33.
The ADDH/ADDL of Relay 1 is 08 and 33 respectively.
So the signal sent by node 1 (08) can be forwarded to node 2 (33)
Also node 1 and node 2 have the same address, so the data sent by node 1 can be received by node 2.
②Secondary Relay
The ADDH\ADDL of relay 2 is 33, 05 respectively.
So relay 2 can forward data from relay 1 to network NETID: 05.
Thus node 3 and node 4 can receive data from node 1. Node 4 outputs data normally, node 3 has a different address to
node 1, so it does not output data.
③Two-way relay
As configured in the figure: data sent by node 1 can be received by nodes 2 and 4, and data sent by nodes 2 and 4 can
also be received by node 1
Copyright ©2012–2023,Chengdu Ebyte Electronic Technology Co.,Ltd.
Signal
Address
Channel
0x0000
0x2E
Relay mode description
23
the over-the-air radio signal for
encryption.