>50mm(2")
>50mm(2")
>50mm(2")
NOTE:Horizontal runs must also have an
anti-siphon air vent(standpipe) install ahead
of the horizontal run to eliminate air
trapping.
NOTE ON DRAINPIPE INSTALLATION
When using an extended drainpipe, tighten
the indoor connection with an additional
protection tube to prevent it from pulling
loose.
The Figure shows how to trap or plug all drains
during vertical discharge.
The Figure shows how to trap or plugall drains
during right-hand discharge.
The seal plug are supplied as accessories and
should be screwed tightly only by hand.
Incorrect installation could cause water to
ow back into the unit and ood.
Using a 65mm (2.5") core drill, drill a hole in
2.
the wall. Make sure that the hole is drilled at
a slight downward angle, so that the outdoor
end of the hole is lower than the indoor end
by about 12mm (0.5"). This will ensure proper
water drainage . Place the
protective wall cu in the hole. This protects
the edges of the hole and will help seal it once
you nish installation.
Outdoor
≈ 12mm / 0.5 inch
NOTE: When drilling the hole, make sure to
avoid wires, plumbing, and other sensitive
components.
Page 32
32
Anti-syphon
air vent
Vent T
Lean over
1/50
Drain Trap
Wall
Indoor
3. Pass the drain hose through the wall hole.
Make sure the water drains to a safe location
where it will not cause water damage or a
slipping hazard.
NOTE: The drainpipe outlet should be at least
5cm (1.9") above the ground. If it touches the
ground, the unit may become blocked and
malfunction. If you discharge the water directly
into a sewer, make sure that the drain has a U
or S pipe to catch odors that might otherwise
come back into the house.