5. Remove T1、T2、T2A、T2B temperature
sensor and electronic expansion valve wire ties.
6. Take out the evaporator and drain pan and
rotate 180°.
7. Adjust the position of the mounting parts.
www.hvacmirage.us
8. Reinstall the evaporator and drain pan.
9. Reinstall T1、T2、T2A、T2B temperature sensor
plug electronic expansion valve and tie up the
temperature sensor wires.
NOTE: The wire body needs to pass through the
wire groove from the water receiving tray and be
stuck on the hook of the water eceiving tray.
Break the sponge.
Remove knockouts as
shown in the gure.
Page 21