Chauvet DJ Intimidator Spot 375ZX User Manual
Chauvet DJ Intimidator Spot 375ZX User Manual

Chauvet DJ Intimidator Spot 375ZX User Manual

Hide thumbs Also See for Intimidator Spot 375ZX:

Advertisement

Quick Links

User Manual

Advertisement

Table of Contents
loading

Summary of Contents for Chauvet DJ Intimidator Spot 375ZX

  • Page 1 User Manual...
  • Page 2 Edition Notes The Intimidator Spot 375ZX User Manual includes a description, safety precautions, installation, programming, operation, and maintenance instructions for the Intimidator Spot 375ZX as of the release date of this edition. Trademarks Chauvet, Chauvet DJ, the Chauvet logo, and Intimidator are registered trademarks or trademarks of Chauvet &...
  • Page 3: Table Of Contents

    Totem Mode ....................... Sensitivity ......................DMX Loss......................Indicator ......................Flash if DMX....................... Reset........................Factory Reset..................... System Information .................... Master/Slave Mode ..................RFC Remote Control..................RFC Remote Control Operation ................. 5. Maintenance..................Product Maintenance ..................Intimidator Spot 375ZX User Manual Rev. 1...
  • Page 4 Table of Contents Gobo Maintenance..................6. Technical Specifications..............Contact Us....................Warranty & Returns..................Intimidator Spot 375ZX User Manual Rev. 1...
  • Page 5: Before You Begin

    Important installation or configuration information. The product may not function correctly if this information is not used. Useful information. Intimidator Spot 375ZX User Manual Rev. 1...
  • Page 6: Safety Notes

    This equipment should be installed and operated with a minimum distance of 20 cm between the radiator and the user. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Intimidator Spot 375ZX User Manual Rev. 1...
  • Page 7: Introduction

    Introduction 2. Introduction Product Overview Carry handles Menu Safety Fuse Power indicator display buttons loop holder in/out Intimidator Spot 375ZX User Manual Rev. 1...
  • Page 8: Product Dimensions

    19 in 458 mm 482 mm 12.3 in 313 mm 9.1 in 230 mm 8.7 in 220 mm 11.4 in 290 mm 18.4 in 466 mm 10 in 19.3 in 255 mm 491 mm Intimidator Spot 375ZX User Manual Rev. 1...
  • Page 9: Setup

    Additional products It is possible to link up to 4 Intimidator Spot 375ZX products on 120 VAC or up to 8 products on 230 VAC. The power linking diagram shown above corresponds to the North American version of the product ONLY! If using the product in other markets, consult with the local Chauvet distributor as power linking connectors and requirements may differ by country or region.
  • Page 10: Mounting

    Before mounting the product, read and follow the safety recommendations indicated in the Safety Notes. Orientation The Intimidator Spot 375ZX may be mounted in any position; however, make sure adequate ventilation is provided around the product. Rigging • Before deciding on a location for the product, always make sure there is easy access to the product for maintenance and programming.
  • Page 11: Gobos

    Setup Gobos Gobo- Rotating Gobo Wheel Rotating Gobo Dimensions 26 mm 21 mm IMAGE Intimidator Spot 375ZX User Manual Rev. 1...
  • Page 12: Gobo Replacement

    This provides a layer of protection against the high temperature from the lamp. • All custom gobos in the Intimidator Spot 375ZX gobo wheel must be aluminum or glass. Procedure Follow the recommended procedure below to remove or replace the gobos: 1.
  • Page 13: Operation

    Press to scroll down the list of options or to find a lower value <ENTER> Press to activate a menu option or a selected value Menu Map Refer to the Intimidator Spot 375ZX product page on www.chauvetdj.com for the latest menu map. Main Level...
  • Page 14 DMX Shows instructions on how to bind the BIND RF remote to the product Reset Resets the product Factory Set Loads factory defaults Intimidator Spot 375ZX User Manual Rev. 1...
  • Page 15: Dmx Configuration

    Displays the current product Temperature: _ _ _ temperature DMX Configuration The Intimidator Spot 375ZX works with a DMX controller. Information about DMX is in the Chauvet DMX Primer, which is available from the Chauvet website chauvetlighting.com/downloads/ DMX_Primer_rev05_WO.pdf. Starting Address The Intimidator Spot 375ZX uses up to 15 DMX channels, which defines the highest recommended address to 498.
  • Page 16: Dmx Charts

    001  063 Gobo indexing 064  145 Gobo rotation (slow to fast) Gobo rotation 146  149 Stop 150  231 Reverse rotation (slow to fast) 232  255 Bounce (slow to fast) Intimidator Spot 375ZX User Manual Rev. 1...
  • Page 17 120  127 Gobo wheel reset 128  135 No function 136  143 Prism reset 144  151 Focus and zoom reset 152  159 All reset 160  255 No function Intimidator Spot 375ZX User Manual Rev. 1...
  • Page 18 200  215 Sound-active movement macro 5 216  231 Sound-active movement macro 6 232  247 Sound-active movement macro 7 248  255 Sound-active movement macro 8 Zoom 000  255 Wide to narrow Intimidator Spot 375ZX User Manual Rev. 1...
  • Page 19: Standalone Configuration

    DMX controller. Products in standalone mode may transmit DMX signals that could interfere with the DMX signals from the controller. Automatic Programs To run the Intimidator Spot 375ZX with a(n) automatic mode, follow the instructions below. 1. Press <MENU>. 2. Use <UP> or <DOWN> to select Run Mode.
  • Page 20: Settings Configuration

    6. Use <UP> or <DOWN> to select from 540 (540°), 360 (360°), or 180 (180°). 7. Press <ENTER>. Tilt Angle To set the tilt angle range on the Intimidator Spot 375ZX , follow the instructions below: 1. Press <MENU>. 2. Use <UP> or <DOWN> to select Setup.
  • Page 21: Sensitivity

    Operation Sensitivity To set the action the Intimidator Spot 375ZX will do when signal is lost, do the following: 1. Press <MENU>. 2. Use <UP> or <DOWN> to select Setup. 3. Press <ENTER>. 4. Use <UP> or <DOWN> to select Sensitivity.
  • Page 22: System Information

    The Master/Slave mode allows a single Intimidator Spot 375ZX product (the “master”) to control the actions of one or more Intimidator Spot 375ZX products (the “slaves”) without the need of a DMX controller. The master product will be set to operate in either the standalone mode or with the RF remote, while the slave products will be set to operate in slave mode.
  • Page 23: Rfc Remote Control Operation

    The RFC remote will not respond to any inputs when Freeze or Black Out is activated. If the remote does not respond when a button is pressed, try pressing <FREEZE> or <BLACK OUT>. Freeze or Black Out may have been inadvertently activated. Intimidator Spot 375ZX User Manual Rev. 1...
  • Page 24: Maintenance

    (needle tip applier recommended). Make sure the gobo holder is rotating freely and is not making any abnormal noise. 8. Reinstall the gobos in the gobo holder. Make sure the gobos are in the correct positions. 9. Reinstall the gobo holder in the unit. Intimidator Spot 375ZX User Manual Rev. 1...
  • Page 25: Technical Specifications

    104 °F (40 °C) Convection I/O Connector Channel Range 3-pin XLR 9 or 15 Ordering Product Name Item Code UPC Number Intimidator Spot 375ZX 08011955 781462223038 UL 1573 CSA C22.2 No. 166 E113093 Intimidator Spot 375ZX User Manual Rev. 1...
  • Page 26: Contact Us

    For warranty terms and conditions and return information, please visit our website. For customers in the United States and Mexico: www.chauvetlighting.com/warranty-registration. For customers in the United Kingdom, Republic of Ireland, Belgium, the Netherlands, Luxembourg, France, and Germany: www.chauvetlighting.eu/warranty-registration. Intimidator Spot 375ZX User Manual Rev. 1...

Table of Contents