Chauvet DJ MAVERICK STORM User Manual
Chauvet DJ MAVERICK STORM User Manual

Chauvet DJ MAVERICK STORM User Manual

3 beamwash
Table of Contents

Advertisement

Quick Links

User Manual
Model ID: MAVERICKSTORM3BEAMWASH

Advertisement

Table of Contents
loading

Summary of Contents for Chauvet DJ MAVERICK STORM

  • Page 1 User Manual Model ID: MAVERICKSTORM3BEAMWASH...
  • Page 2 Edition Notes The Maverick Storm 3 BeamWash User Manual includes a description, safety precautions, installation, programming, operation, and maintenance instructions for the Maverick Storm 3 BeamWash as of the release date of this edition. Trademarks Chauvet, Chauvet Professional, the Chauvet logo, Maverick, and Maverick Storm 3 BeamWash are registered trademarks or trademarks of Chauvet &...
  • Page 3: Table Of Contents

    Control Mode...................... 16 Control Personalities ..................16 Starting Address....................17 Network Setup....................IP Mode......................17 Manual IP Address ..................... 17 Subnet Mask ...................... 17 Control Channel Assignments and Values............ Pixel Chart......................18 Maverick Storm 3 BeamWash User Manual Rev. 3...
  • Page 4 Offset Mode....................Web Server ....................5. Maintenance................Product Maintenance ..................Torque Measurements .................. Vacuum Test Measurements ................ Transporting on Truss or Racks..............6. Technical Specifications ............Contact Us ..................Warranty & Returns..................Maverick Storm 3 BeamWash User Manual Rev. 3...
  • Page 5: Before You Begin

    Any reference to data or power connections in this manual assumes the use of Seetronic IP-rated cables. The term “DMX” used throughout this manual refers to the USITT DMX512-A digital data transmission protocol. Maverick Storm 3 BeamWash User Manual Rev. 3...
  • Page 6: Safety Notes

    • In the event of a serious operating problem, stop using immediately. If a Chauvet product requires service, contact Chauvet Technical Support. Maverick Storm 3 BeamWash User Manual Rev. 3...
  • Page 7: Fcc Statement Of Compliance

    The average LED lifespan is 40,000 to 50,000 hours. To extend LED lifespan, maintain proper ventilation around the product, and limit the overall intensity. Maverick Storm 3 BeamWash User Manual Rev. 3...
  • Page 8: Introduction

    Dual mode operation enables pixel-mapped eye candy to run under ArtNet/sACN control with separate assignment of motorized functions to DMX. Housed in an advanced IP65-rated alloy body, Maverick Storm 3 BeamWash is built with the durability and versatility to perform in any venue, indoors or out.
  • Page 9: Product Dimensions

    19 in 482 mm 10 in 254 mm 15.9 in 404 mm 20.8 in 527 mm 4.6 in 117 mm 18.3 in 465 mm 14.8 in 375 mm 11.9 in 303 mm Maverick Storm 3 BeamWash User Manual Rev. 3...
  • Page 10: Setup

    Green/Yellow Green/Yellow Green Power Linking It is possible to power link Maverick Storm 3 BeamWash products. See the table below for the current draw at each voltage and frequency: 100 V, 60 Hz 120 V, 60 Hz 208 V, 60 Hz...
  • Page 11: Signal Connections

    DMX controller, download the DMX Primer from the Chauvet website: www.chauvetprofessional.com. DMX Linking The Maverick Storm 3 BeamWash can link to a DMX controller using a 5-pin DMX connection or a WDMX connection. For more information about DMX, read the DMX primer at: https://www.chauvetprofessional.com/wp-content/uploads/2016/06/DMX_Primer.pdf.
  • Page 12: Connection Diagram

    To other Art-Net™ or sACN devices USB Software Update The Maverick Storm 3 BeamWash allows for software updates with a USB device using the built-in USB port. To update the software using a USB flash drive, do the following: 1. Power on the product, and plug the flash drive into the USB port.
  • Page 13: Operation

    The technician mode disables the pan/tilt motors, allowing the output of the product to be aimed by hand. To enable the technician mode of the Maverick Storm 3 BeamWash, hold <UP> and <LEFT> while the product is powering on. When the product is turned off and back on, the pan and tilt will return to normal function.
  • Page 14: Menu Map

    Operation Menu Map Refer to the Maverick Storm 3 BeamWash product page on www.chauvetprofessional.com for the latest menu map. Programming Levels Description Control Settings Control Settings Main Level Basic Standard Advanced Sets the DMX personality: Personality Tour (see Control Personalities)
  • Page 15 Personality Standard (see Control Personalities) sACN Advanced Start Address 1–512 Sets the sACN starting address Universe 0–255 Sets the sACN universe Basic Sets the Kling-Net personality: Kling-Net Personality (see Control Personalities) Standard Maverick Storm 3 BeamWash User Manual Rev. 3...
  • Page 16 Do not swap pan and tilt Swap XY Pan controls tilt, tilt controls pan Lock the buttons and touch screen Lock Screen Passcode: 0920 Do not reset WDMX WDMX Reset Reset WDMX Maverick Storm 3 BeamWash User Manual Rev. 3...
  • Page 17 Maverick Storm 3 BeamWash products in the DMX daisy chain USB Update Update firmware via USB-C Pan/Tilt Reset individual functions or all Reset Function Zoom functions from start-up Factory Reset to factory default settings Settings Maverick Storm 3 BeamWash User Manual Rev. 3...
  • Page 18 _ _ _ _ Base Fan2 Speed _ _ _ _ Base Fan3 Speed _ _ _ _ Base Fan4 Speed _ _ _ _ Error No Error!* Shows any errors, or No Error! Information Maverick Storm 3 BeamWash User Manual Rev. 3...
  • Page 19 Dimmer Fine (all, 1–28) Red (all, 1–28) Red Fine (all, 1–28) Green (all, 1–28) Green Fine (all, 1–28) Blue (all, 1–28) Blue Fine (all, 1–28) White (all, 1–28) White Fine (all, 1–28) Maverick Storm 3 BeamWash User Manual Rev. 3...
  • Page 20: Control Configuration

    Use control configurations to operate the product with a DMX, WDMX, Art-Net™, Kling-Net, and sACN control signals. Control Mode The Maverick Storm 3 BeamWash works with wired DMX, WDMX, Art-Net™, Kling-Net, and sACN control signals. To select which single control protocol to use: 1. Go to the Control Settings main level.
  • Page 21: Starting Address

    3. Set the 4 values of the IP address from 000–255. Subnet Mask To set the subnet mask: 1. Go to the Network Setting level. 2. Select the SubMask option. 3. Set the 4 values of the subnet mask from 000–255. Maverick Storm 3 BeamWash User Manual Rev. 3...
  • Page 22: Control Channel Assignments And Values

    12 12 000 255 See Color Chart Background color (inner plate) 13 13 15 Background dimmer (ring) 000  255 0–100% Background dimmer fine – – – 000  255 0–100% (ring) Maverick Storm 3 BeamWash User Manual Rev. 3...
  • Page 23 000  255 0–100% 22 26 39 White (inner plate) 000  255 0–100% 40 White fine (ring) 000  255 0–100% – 27 41 White fine (inner plate) 000  255 0–100% Maverick Storm 3 BeamWash User Manual Rev. 3...
  • Page 24: Single Control Values

    000  255 0–100% – 22 22 31 Red fine (inner plate) 000  255 0–100% 23 23 32 Green (ring) 000  255 0–100% 23 23 33 Green (inner plate) 000  255 0–100% Maverick Storm 3 BeamWash User Manual Rev. 3...
  • Page 25 – 54 62 77 Red fine 4 000  255 0–100% 36 55 63 78 Green 4 000  255 0–100% – 56 64 79 Green fine 4 000  255 0–100% Maverick Storm 3 BeamWash User Manual Rev. 3...
  • Page 26 – 92 108 123 White fine 8 000  255 0–100% – – 109 124 Dimmer 9 000  255 0–100% – – 110 125 Dimmer fine 9 000  255 0–100% Maverick Storm 3 BeamWash User Manual Rev. 3...
  • Page 27 – 128 154 169 Green fine 13 000  255 0–100% 73 129 155 170 Blue 13 000  255 0–100% – 130 156 171 Blue fine 13 000  255 0–100% Maverick Storm 3 BeamWash User Manual Rev. 3...
  • Page 28 – – 200 215 Dimmer fine 18 000  255 0–100% 91 165 201 216 Red 18 000  255 0–100% – 166 202 217 Red fine 18 000  255 0–100% Maverick Storm 3 BeamWash User Manual Rev. 3...
  • Page 29 – 202 246 261 Blue fine 22 000  255 0–100% 110 203 247 262 White 22 000  255 0–100% – 204 248 263 White fine 22 000  255 0–100% Maverick Storm 3 BeamWash User Manual Rev. 3...
  • Page 30 – 238 292 307 Red fine 27 000  255 0–100% 128 239 293 308 Green 27 000  255 0–100% – 240 294 309 Green fine 27 000  255 0–100% Maverick Storm 3 BeamWash User Manual Rev. 3...
  • Page 31 – 250 306 321 Blue fine 28 000  255 0–100% 134 251 307 322 White 28 000  255 0–100% – 252 308 323 White fine 28 000  255 0–100% Maverick Storm 3 BeamWash User Manual Rev. 3...
  • Page 32: Dual Control Movement Values

    000  255 0–100% – – 26 Main blue fine 000  255 0–100% – 27 Main white 000  255 0–100% – – 28 Main white fine 000  255 0–100% Maverick Storm 3 BeamWash User Manual Rev. 3...
  • Page 33: Dual Control Pixels Values

    41 Red 6 000  255 0–100% – – 42 Red fine 6 000  255 0–100% 43 Green 6 000  255 0–100% – – 44 Green fine 6 000  255 0–100% Maverick Storm 3 BeamWash User Manual Rev. 3...
  • Page 34 87 White 11 000  255 0–100% – – 88 White fine 11 000  255 0–100% 89 Red 12 000  255 0–100% – – 90 Red fine 12 000  255 0–100% Maverick Storm 3 BeamWash User Manual Rev. 3...
  • Page 35 000  255 0–100% – – 134 Blue fine 17 000  255 0–100% – 135 White 17 000  255 0–100% – – 136 White fine 17 000  255 0–100% Maverick Storm 3 BeamWash User Manual Rev. 3...
  • Page 36 179 Green 23 000  255 0–100% – – 180 Green fine 23 000  255 0–100% 181 Blue 23 000  255 0–100% – – 182 Blue fine 23 000  255 0–100% Maverick Storm 3 BeamWash User Manual Rev. 3...
  • Page 37 000  255 0–100% – – 222 Blue fine 28 000  255 0–100% – 112 223 White 28 000  255 0–100% – – 224 White fine 28 000  255 0–100% Maverick Storm 3 BeamWash User Manual Rev. 3...
  • Page 38: Color Chart

    110  124 Random strobe, fast to slow 225  229 On 125  129 On 230  244 Pulse strobe 2, fast to slow 130  144 Random 100–0% strobe, fast to slow 245  255 On Maverick Storm 3 BeamWash User Manual Rev. 3...
  • Page 39: Control Chart

    When preset color HTP is on, manual color controls may be used at the same time as preset color controls. When preset color HTP is off, preset color controls will override all manual color controls. Maverick Storm 3 BeamWash User Manual Rev. 3...
  • Page 40: Configuration

    3. Select from NO or YES. WDMX Reset To reset the WDMX connection: 1. Go to the Setup main level. 2. Select the WDMX Reset option. 3. Select from NO or YES. Maverick Storm 3 BeamWash User Manual Rev. 3...
  • Page 41: Display Backlight Timer

    2. Select the Calibrated White option. 3. Select from ON (uses the factory-calibrated white balance), OFF (uses the maximum white values), or Custom (uses the custom white values defined under White Balance) Maverick Storm 3 BeamWash User Manual Rev. 3...
  • Page 42: White Balance

    2. Select the Preset Sync option. 3. Select NO or YES. • To sync other Maverick Storm 3 BeamWashes, connect those products via DMX cable. • The product can be in any control mode except WDMX. ArtNet, DMX, sACN are all acceptable.
  • Page 43: Factory Reset

    3. Select NO (to cancel) or YES (to reset the product configuration). Test Mode Auto Test To have the Maverick Storm 3 BeamWash automatically test all functions one after the other: 1. Go to the Test Mode main level. 2. Select the Auto Test option.
  • Page 44: Web Server

    Operation Web Server The Maverick Storm 3 BeamWash Web Server can be accessed by any computer on the same network as the product. It allows network access to system information, settings such as control setup, manual testing of all functions, firmware updates, and the ability to change the Web Server password.
  • Page 45: Maintenance

    To ensure that the product has been reassembled correctly, use the IP Tester from Chauvet Professional to check the following data has the given measurements for the given method: Parameters Values Method Positive Test pressure 2.18 kPa Test duration 60 seconds PASS state leak pressure <0.02 kPa Maverick Storm 3 BeamWash User Manual Rev. 3...
  • Page 46: Transporting On Truss Or Racks

    This is to prevent undue stress on the tilt locks and limit the amount of off-axis bounce on internal components. Maverick Storm 3 BeamWash User Manual Rev. 3...
  • Page 47: Technical Specifications

    5-pin IP-rated XLR Neutrik IP-rated RJ45 84Ch, 24Ch-112Ch, or 30Ch-224Ch Ordering Product Name Item Name Item Code UPC Number Maverick Storm 3 BeamWash MAVERICKSTORM3BEAMWASH 08011994 781462223427 UL 1573 CSA C22.2 No. 166 E113093 Maverick Storm 3 BeamWash User Manual Rev. 3...
  • Page 48: Contact Us

    For warranty terms and conditions and return information, please visit our website. For customers in the United States and Mexico: www.chauvetlighting.com/warranty-registration. For customers in the United Kingdom, Republic of Ireland, Belgium, the Netherlands, Luxembourg, France, and Germany: www.chauvetlighting.eu/warranty-registration. Maverick Storm 3 BeamWash User Manual Rev. 3...

This manual is also suitable for:

Maverick storm 3 beamwash

Table of Contents