PROXIMITY TO SIDE CABINET INSTALLATION

1. This rangetop may be installed directly adjacent to existing 36" (91.4 cm) high base cabinets. IMPORTANT: : The
top grate support MUST be 3/8" (.95 cm) above the adjacent base cabinet countertop.
2. The rangetop CANNOT be installed directly adjacent to sidewalls, tall cabinets, tall appliances, or other side vertical
surfaces above 36" (91.4 cm) high. There must be a minimum of 6" (15.2 cm) side clearance from the rangetop to
such combustible surfaces above the 36" (91.4 cm) counter height.
3. Within the 6" (15.2 cm) side clearance to combustible vertical surfaces above 36" (91.4 cm) , the maximum wall
cabinet depth must be 13" (33.0 cm) and wall cabinets within this 6" (15.2 cm) side clearance must be 18" (45.7 cm)
above the 36" (91.4 cm) high countertop.
4. Wall cabinets above the rangetop must be a minimum of 36" (91.4 cm) above the rangetop cooking surface for the
full width of the rangetop. This minimum height requirement does not apply if a rangehood is installed over the
cooking surface.
A
VERT
7 1/2"
19.1 cm)
DERT
5 3/4"
(14.6 cm)

ELECTRICAL REQUIREMENTS

Check your national and local codes regarding this unit. This rangetop is supplied with a 3 wire conduit which is
equipped with a No. 10 ground wire. See next section for grounding instructions. This unit should be fused
separately. CAUTION: Be sure the electrical power is off from the breaker box to the junction box until the unit is
installed and ready to operate. The junction box should be located as shown in the drawing and connected to a
suitable ground.
A A
B
24"
(61.0 cm)
24 7/16"
(62.1 cm)
4