Table 4.6
Error
Code
Error 34
Error 35
Error 37
Error 38
Error 39
Error 40
For additional information about alarms, refer to the 2000 IW/IW+ Series Inte-
grated Welder Operating Manual, EDP 1019568.
62
Error Codes
IW
IW+
Collapse Limited Setup Error
Latchable - Value for minus
x
limit greater than value for
plus limit, or plus limit less
than nominal value.
Absolute Limit Setup Error
Latchable - Value for minus
x
limit greater than value for
plus limit, or plus limit less
than nominal value.
TRS Lost Error Latchable -
TRS was lost during weld
x
time, hold time, or horn
down.
ULS Weld Error Latchable -
x
ULS was active during weld
time or during hold time.
ULS Active Error Latchable -
ULS became active while
x
waiting for the TRS after the
ULS was already inactive.
START SWITCH 1 Lost Error
Non-Latching - START
x
SWITH 1 was lost before the
trigger became active.
Description
Cause/Solution
• Check -Limit and +Limit
values
• Check Collapse settings
• Contact Branson Applications
Lab or local Branson
representative
• Check -Limit and +Limit
values
• Check Absolute setting
• Contact Branson Applications
Lab
• Adjust Trigger pressure
setting
• Check TRS; replace if faulty
• Check Controller Board;
replace if faulty
• Consider selecting TRS=EDGE
instead of TRS=LEVEL (refer
to the 2000 IW/IW+
Operating Manual
• Check ULS; clean if dirty,
replace if faulty
• Check Controller Module;
replace if faulty
• Check ULS; clean if dirty,
replace if faulty
• Check Controller Module;
replace if faulty
• Check air pressure
• Check SV; repair or replace if
faulty
• Check START SWITCHES or
remote START switches
• Make sure to keep pressing
both START SWITCHES or
remote START switches until
triggering occurs
• Check Controller Module;
replace if faulty
1019567 REV. 03