Emerson 2000IW Maintenance Manual page 31

Integrated welder
Table of Contents

Advertisement

Table 2.1
Item
3
Down Speed Control
4
Autotune Label
5
Front Panel Displays
6
Stroke Indicator
7
Trigger Pressure Control
8
Carriage Door
Mechanical Stop Locking
9
Nut
10
Mechanical Stop
This multi-turn control is calibrated in color rings, visible in slots.
1019567 REV. 03
Front Panel Controls
Name
Function
Controls rate of carriage descent, multi-turn
color coded, each turn calibrated at 0-9. Pull red
locking ring to set; push locking ring to lock.
Return rate is fixed.
Refer to
6.1.4 Manual Tuning
Manual.
Refer to next section.
Provides a quick method of determining relative
carriage travel during a weld cycle; indicates 0 -
4 in. (0 - 100 mm)
Selects dynamic triggering pressure; calibrated
1-24 in half-steps/48 detents corresponding to a
force range of 15-200 lbs/67-890 N.
Provides access to the converter-booster-horn
stack; secured by 4 captive hex screws.
Locks the mechanical stop to desired depth.
Limits the distance the carriage travels to
prevent the horn from contacting the fixture or
nest when no workpiece is in place; adjustment
is approximately 0.04 in/1 mm per rotation.
of your Operating
21