5. Use an Allen wrench to remove the two shipping spacer retaining screws
Spacers)
6. Plug the encoder cable connector into socket J42 on the Control Module
7. Install tie wraps to attach the encoder cable to the Main Harness
CAUTION
8. Close the left side cover. See
9. Install the two shipping spacers on the faulty encoder. Install each shipping spacer as follows:
• insert a retaining screw through the Body section
• insert the shipping spacer between the sections
• While pushing down on the screw; slide the Read section until the screw catches in the shipping
spacer hole; and tighten the screw
10.Return the failed encoder to Branson's repair department
1019567 REV. 03
General Warning
Make sure you install enough tie wraps so the encoder cable does not
get pinched by carriage movement.
5.3 Opening and Removing the Left Side Cover (EDP
(Figure 5.34 Shipping
Spacers)
(Figure 5.34 Shipping
Spacers)
(Figure 5.34 Shipping
100-032-338).