3.6
Individual Operations of Maintenance
Every 50 hours of operation
3.6.11 Inspection of brakes
The function of the brakes must be checked periodically.
The cable / connector Y9, which must be disconnected for
the brake test, is located at the front under the hood.
Put the machine into the work gear.
Disconnect connector Y9 from the connector housing at the
magnet.
Use the sensor to activate the forward and reverse travel
function.
If a brake is defective, the corresponding drum will rotate.
If the brake is damaged, the machine must not be oper-
ated until the fault is rectified!
3.6.12 Electrical installation check
Check cables, connectors, protective hoses and their attach-
ments for damage, in particular if they are near hot surfaces
and moving parts of the machine including the engine. Re-
place damaged parts. Use only original spare parts.
100