5-2 Mechanical Adjustment
Note : Refer to the Mechanical Manual for the adjustment and confirmation of Ass'y deck.
5-2-1 The number and position of test point
Test point :
TP602 (H'D S/W -Trigger)
TP301 (Envelope)
TP302 (Audio output)
ieee
|
ue.
A.
=
ENVELOPE
LL HEAD SWITCHING
|
Fig. 5-4 Location of Test point (Main PCB-Top View)
5-2-2 ACE Head Position (X-Point) Adjustment
4) Connect the CH-1 probe to TP301 (Envelope) the
(See the 5-2-1(d) ACE Head Position (X-Point) Adjustment on
CH-2 probe to TP602 (H'D switching pulse) and
page 5-2 of the Mechanical Manual)
hen trigger to CH-1.
5) Insert the (-) driver into the X-Point adjustment
1) Playback the alignment tape (Color bar).
hole and adjust it so that envelope waveform is
2) Press the "TEST" button on Main PCB/Function PCB
maximum.
to set the adjustment mode.
6) Turn the Power off.
(See Fig. 5-2 and 5-3)
3) Press the "5" button of remote control then adjust-
ment is operated automatically. (See Fig. 5-1)