Download Print this page

Viking K-1900-3 Technical Practice page 4

Door entry dialer
Hide thumbs Also See for K-1900-3:

Advertisement

3. Programming a Keyless Entry Code Without a Phone Number
You are allowed to program a keyless entry code in a memory location without programming a phone number. This
is useful when you need to assign keyless entry codes for people that are not tenants in the complex (guards,
maintenance workers, etc.) The memory location then becomes dedicated to keyless entry storage. This is pro-
grammed by entering "#," (skipping the phone number entry) + the keyless entry code (4 - 6 digits) + "#" + the
memory location (000 - 149). Example: #, 123456 # 001
4. Adding a Master Keyless Entry Code
The master keyless entry code is simply an additional keyless entry code in memory position 150. This is useful
when you have a full 150 tenants and require one additional entry code for a non-tenant (guard, maintenance work-
er, etc.) This is programmed by entering "#," (skipping the phone number entry) + the keyless entry code (4 - 6
digits) + "#" + the memory location 150. Example: #, 123456 # 150
5. Deleting the Phone Number and/or Keyless Entry Code for One Memory Location
While in programming dial a "#" + memory location (000 - 150) to clear.
Note: It is not possible to erase only the phone number or the keyless entry number. If either number needs to
be changed, BOTH numbers must be reprogrammed.
6. Deleting All Phone Numbers and Keyless Entry Codes
While in programming, enter "###".
! Caution: All phone numbers and keyless entry codes will be permanently erased.
D. Programming Features Quick Reference
Features
Tenant's phone numbers: 000 (0-30 digits), 001-149 (0-14 digits) ..........
Tenant's phone numbers and keyless entry codes ..................................
Keyless entry code only (4 - 6 digits) .......................................................
Master keyless entry code (4 - 6 digits) ...................................................
Clear all phone numbers and keyless entry codes from memory ............
Clear one phone number and/or keyless entry code ...............................
PABX line access number: one digit + 3 sec pause (factory disabled) ....
Relay activation time: 1/2-99 sec (00 = 1/2 sec, factory set to 5 sec) ......
Relay activation code:
Security code (factory set to 845464) ......................................................
Maximum call time : 0-99 min (00 = disabled, factory set to 2 min) ..........
To exit programming ...............................................................................
Apartment dialer mode (factory setting) ..................................................
Multi-number dialer mode .......................................................................
Ring thru mode OFF (factory setting) ......................................................
Ring thru mode ON .................................................................................
To add a 4 second pause anywhere in the dialing string .........................
To add a 1 second pause anywhere in the dialing string .........................
To add a , at any point in the dialing string .............................................
To add a # at any point in the dialing string ..............................................
The relay may be activated with a single digit, but must be programmed with a "0" + the digit (see section E, exam-
(1)
ple 3). When a single digit relay activation code is programmed (0-9), the activation Touch Tone must be held for a
minimum of 150 milliseconds.
Notes: Each pause uses a single digit. To clear a memory location, enter only the location (no digits). A valid pro-
gramming entry will be indicated by a double beep. An invalid entry will be indicated with three beeps.
two digits (factory set to 36) .............................
(1)
Enter Digits
- then -
phone number
phone number + #, + entry code+
#, + entry code
#, + entry code
###
(Caution: Permanently erases ALL programming!)
(no digits)
1 digit (0 - 9)
2 digits (00 - 99)
2 digits (00 - 99)
6 digits (0 - 9)
2 digits (00 - 99)
(no digits)
,3
,4
,5
,6
,7
,8
,,
,#
Memory
Location
+
#000-149
#000-149
+
#000-149
+
#150
+
#000-150
+
##2
+
##3
+
##4
+
##5
+
##6
+
##7

Hide quick links:

Advertisement

loading