Basic Wiring - Viking ES-3 Technical Practice

Entry system door controller
Hide thumbs Also See for ES-3:
Table of Contents

Advertisement

I
n
s
t
a
l
l
a
t
i
o
I
n
s
t
a
l
l
a
t
i
o
A. Basic Wiring
12VDC, 500mA
Adapter (included)
CAN communications
from AES-NET board
CAN L
CAN H
Door Strike
Power Supply
12-24V AC or DC
A basic door access controlled entry point is wired as shown above. The ES-3 is designated to share power
with the attached door strike or magnetic lock. Voltage needs to be between 12-24 Volts with an additional
300 mA of current available or use the included 12V DC adapter.
Relays can be set as either Normally Open (NO), or Normally Closed (NC) using the shunt located directly
behind the relay screw terminals.
The Wiegand device (typically a proximity card reader) is fully supported (power and data) from the ES-3 and
can be installed up to 500 feet away using 24 gauge wire.
The ES-3 communicates with the AES-2000 through the AES-NET board via a two wire CAN
Communication Bus. CAN bus distances of up to 1/2 a mile (over 2600 feet) are achieved using common 24
gauge CAT-2 through CAT-5 wire, and 1 mile (5280 feet) is possible by doubling up on the 24 gauge twist-
ed pair (or running at least 21 gauge). In addition, up to 32 ES-3 entry system door controllers may share
the same CAN communication pair.
n
n
VIKING
ENTRY LOCATION
STATUS LED
GROUP
POWER
CAN
COMM
INPUT
12-24V
L
H
BLK RED GRN WHT
AC or DC
CAN
or
Doorstrike/Magnetic Lock (not included)
MODEL ES-3
©
VIKING
ELECTRONICS
HUDSON, WI 54016
ENTRY SYSTEM
DOOR CONTROLLER
INPUTS
RELAY OUTPUTS
S1
LO HI
C
C
C
C
C
WIEGAND
DEVICE
JP6
JP4
JP5
JP1
JP2
JP3
REQUEST
DOOR
RELAY
RELAY
RELAY
WEIGAND DEVICE
TO EXIT
SENSOR
1
2
3
To Wiegand Device
Shunt
Selections
Normally
Open
Normally
Closed
HID-1
Card Reader
White
Green
Red
HID
Black
(not included)
HID-2
Keypad
1
2
3
4
5
6
and/or
7
8
9
0
*
#
Up to 31 additional
ES-3 Controllers
may be added