Viking ES-3 Technical Practice
Viking ES-3 Technical Practice

Viking ES-3 Technical Practice

Entry system door controller
Hide thumbs Also See for ES-3:

Advertisement

Quick Links

TECHNICAL
TECHNICAL
T
T
E
L
E
E
L
Up to 525 valid Wiegand codes can be programmed into the AES-2000, and up to 1024 access
entry events are logged and stored in the AES-2000. Other programmable parameters, like relay
activation and delay times, are also PC programmed via the AES-2000.
Only one pair of wires are needed to wire all 32 Entry System Door Controllers back to the AES-
2000. This two wire CAN communication protocol allows the ES-3 to be installed up to 1 mile
away. A door sensor input monitors for a forced door or door ajar condition. A Request to Exit input operates the
doors for people leaving the controlled area. Three separate relay outputs allow control of Door Strikes, Magnetic
Locks, Gate Opener, Lights, Camera and or Alarm. Power to the ES-3 can be daisy chained from unit to unit on
a single pair of wires, or simply tap into the local door
strike's power supply.
F
e
a
t
u
r
e
s
F
e
a
t
u
r
e
s
• Up to 525 tenants
• Up to 32 entry points are possible
• logs up to 1024 entry events
• Two wire CAN communication protocol can
be daisy-chained together
• Use supplied power adapter or share with door
strike's 12-24 Volt AC or DC power source
• Inputs may be either normally open (NO) or
normally closed (NC) contacts
• Relay outputs provide either normally open
(NO) or normally closed (NC) contacts
P
h
o
n
e
.
.
.
7
1
5
.
3
8
6
P
h
o
n
e
.
.
.
7
1
5
.
3
8
6
h
t
t
p
:
/
/
w
w
w
.
v
i
k
i
n
g
h
t
t
p
:
/
/
w
w
w
.
v
i
k
i
n
g
S
S
C
O
M
O
L
U
T
I
O
N
S
E
C
O
M
O
L
U
T
I
O
N
Add Up To 32 Access Entry Points
To Vikings Accessible Entry System
.
8
8
6
1
.
8
8
6
1
e
l
e
c
t
r
o
n
i
c
s
.
c
o
m
e
l
e
c
t
r
o
n
i
c
s
.
c
o
m
P
r
a
P
r
a
2
1
2
1
F
O
R
T
H
E
S
T
S
F
O
R
T
H
E
S
T
Up to 32 additional points of entry can be added to
Viking's model AES-2000 Accessible Entry System.
One ES-3, one Wiegand device and a door strike or
magnetic lock of your choice is required for each addi-
tional entry point.
The ES-3 is an entry system door controller designed to
operate a door strike or magnetic lock upon receiving a
valid card read from a Wiegand device. The Wiegand
device used may be the Viking model HID-1 Proximity
Card Reader or any other card reader, RF transmitter or
digital keypad that outputs the 26 bit Wiegand format.
A
p
p
A
p
p
• High rise apartment buildings
• Condos
• Senior citizen buildings
• Assisted care centers
• Retirement homes
• Gated communities
S
p
e
c
S
p
e
Power: Any 12-24 Volt AC or DC source @ 300mA, 12V DC
adapter included (Designed to share power with the local door
strike's power supply)
Dimensions: 133mm x 89mm x 44mm (5.25" x 3.5" x 1.75")
Shipping Weight: 1.3 kg (3 lbs)
Environmental: 0° C to 32° C (32° F to 90° F) with 5% to 95%
non-condensing humidity
Relay Contact Ratings: 3A @ 30V DC/250V AC maximum
Connections: 18 screw terminals
Maximum CAN Length: 0.8 Km (2600 ft) - 24 AWG twisted pair,
1.6 Km, (5300 ft) - using 2 pairs of 24 AWG twisted pair
Maximum Wiegand Length: 183 m (500 ft) - 24 AWG
Entry System
c
t
i
c
e
c
t
i
c
e
Door Controller
C
C
E
N
T
U
R
Y
E
N
T
U
R
Y
l
i
c
a
t
i
o
n
s
l
i
c
a
t
i
o
n
s
i
n
f
o
@
v
i
k
i
n
g
i
n
f
o
@
v
i
k
i
n
g
i
f
i
c
a
t
i
o
n
s
c
i
f
i
c
a
t
i
o
n
s
ES-3
ES-3
November 20, 2003
e
l
e
c
t
r
o
n
i
c
s
.
c
o
m
e
l
e
c
t
r
o
n
i
c
s
.
c
o
m

Advertisement

Table of Contents
loading

Summary of Contents for Viking ES-3

  • Page 1 Three separate relay outputs allow control of Door Strikes, Magnetic Locks, Gate Opener, Lights, Camera and or Alarm. Power to the ES-3 can be daisy chained from unit to unit on a single pair of wires, or simply tap into the local door strike’s power supply.
  • Page 2: Warranty

    Viking warrants its products to be free from defects in the workmanship or materials, under normal use and service, for a period of one year from the date of purchase from any authorized Viking distributor or 18 months from the date manufactured, which ever is greater. If at any time during the warranty period, the product is deemed defective or malfunctions, return the product to Viking Electronics, Inc., 1531 Industrial Street, Hudson, WI., 54016.
  • Page 3: Basic Wiring

    CAT-2 through CAT-5 wire, and 1 mile (5280 feet) is possible by doubling up on the 24 gauge twist- ed pair (or running at least 21 gauge). In addition, up to 32 ES-3 entry system door controllers may share the same CAN communication pair.
  • Page 4: Advanced Wiring

    Door Sensor screw terminals to either Normally Open (NO), or Normally Closed (NC). The ES-3 can be wired with either a normally open or a normally closed Request to Exit device switch by setting the shunt located directly behind the Request to Exit screw terminals to either Normally Open (NO), or Normally Closed (NC).
  • Page 5: Access Cards

    A. Assignment Each ES-3 (up to 32 total) must be assigned with its own unique entry point location identifier. With the shunt set to Low Group, 16 different rotary switch positions are available. After these 16 have been used, set the remaining units to the High Group for 16 more settings using the same rotary switch.
  • Page 6: Creating Zones

    If both a request to exit device and a door sensor switch are used, a Forced Door alarm condition may be select- ed. If the door is opened other than by the ES-3, Relay 3 will activate for either 1 second or until the door clos- es (programmable).
  • Page 7 Call (715) 386-4345 and select 199. Due to the dynamic nature of the product design, the information contained in this document is subject to change without notice. Viking Electronics, and its affiliates and/or subsidiaries assume no responsibility for errors and omissions contained in this information. Revisions of this document or new editions of it may be issued to incorporate such changes.

Table of Contents