B. Advanced Wiring
"Push to Open"
button, push bar, switch
or motion sensor
The ES-3 can be wired with either a normally open or a normally closed Door Sensor switch by setting
the shunt located directly behind the Door Sensor screw terminals to either Normally Open (NO), or
Normally Closed (NC).
The ES-3 can be wired with either a normally open or a normally closed Request to Exit device switch by
setting the shunt located directly behind the Request to Exit screw terminals to either Normally Open
(NO), or Normally Closed (NC).
Relay 2 can provide either a Normally Open (NO), or Normally Closed (NC) contacts to control (switch
on) a courtesy light, a gate/door opener, a second door strike/magnetic lock, or start a camera. Use the
shunt located directly behind the relay screw terminals to set the normal state.
Relay 3 can provide either a Normally Open (NO), or Normally Closed (NC) contacts to trigger an alarm,
activate a security panel lamp, or start a camera. Use the shunt located directly behind the relay screw
terminals to set the normal state.
VIKING
MODEL ES-3
©
VIKING
ELECTRONICS
HUDSON, WI 54016
ENTRY SYSTEM
DOOR CONTROLLER
ENTRY LOCATION
STATUS LED
INPUTS
GROUP
S1
LO HI
C
C
CAN
WIEGAND
POWER
INPUT
COMM
DEVICE
JP6
JP4
JP5
12-24V
L
H
BLK RED GRN WHT
REQUEST
DOOR
AC or DC
CAN
WEIGAND DEVICE
TO EXIT
SENSOR
Magnet
Door Switch
RELAY OUTPUTS
C
C
C
JP1
JP2
JP3
RELAY
RELAY
RELAY
1
2
3
Magnetic Lock or Camera
Shunt
Selections
Normally
Open
Normally
Closed
Alarm Panel,
Security Panel Lamp
or Camera
Courtesy Lights,
Gate/DoorOpener,
Second Door Strike/