IMPORTANT: Electronic devices are susceptible to lightning and power station electrical surges from both the AC outlet and the
!
telephone line. It is recommended that a surge protector be installed to protect against such surges. Contact Panamax at (800)
472-5555 or Electronic Specialists Inc. at (800) 225-4876.
* Note: Maximum Wiegand run length is 2000 feet using 24 gauge wire when using the Viking Model HID-1 proxy card reader, and 4000
feet for the HID-2 keypad. Run length is reduced in half if two share the same wire run from the same ES-1 entry point. Run length will
also be reduced if using a Wiegand device other than the Viking Model HID-1, that requires more than 35mA average operating current.
Run lengths can be doubled by doubling up on the BLACK and RED 24 gauge wire, or using 21 gauge (or larger) wire. Certain electri-
cally noisy locations might require shielded wire.
A. Basic Wiring
A basic door access controlled entry point is wired as shown below. The relay can be connected as either Normally
Open, or Normally Closed. All 26-bit Wiegand devices are fully supported (power and data) from the ES-1 and can be
installed up to 500 feet away using 24 gauge wire. Viking Wiegand devices can run even further (see Note above).
The ES-1 can support either a card reader (Viking model HID-1) or a keyless entry keypad (Viking model HID-2), or
both. If both are installed, the "Card Plus Keypad" mode can be used. If any two Wiegand devices are used, one can
be placed on each side of a doorway/gate for bi-directional (entry and exit) access control.
Doorstrike
Power Supply
5A@30VDC/250VAC
maximum
(not included)
(Power typically not
required for gate
controllers.)
Remote Touch Tone
RAD-1 Remote Access
Programming Phone
Device (not included)
B. Gang Programming Wiring
If multiply ES-1s are installed to handle door access control for multiple entry points, two or three of them can be pro-
grammed simultaneously if they are to be programmed identically. Do this by wiring GANG PROG COMM screw ter-
minals 1 together, and screw terminals 2 together. The touch tone programming phone connected to any one of them
will program all of them simultaneously.
VIKING
©
VIKING
ELECTRONICS
HUDSON, WI 54016
STAND-ALONE
DOOR CONTROLLER
ENTRY SYSTEM
LOG
BUS
PROGRAM
PHONE
Touch Tone
Programming
Phone
n
n
12V DC
Adapter
Included
or
Doorstrike/Magnetic Lock
(not included)
Touch Tone
Programming Phone
VIKING
MODEL ES-1
ENTRY POINT
WIEGAND
DEVICE
GANG
PROG
COMM
PROGRAM
PHONE
1
2
609m (2000 ft) maximum
with 24 gauge wire
VIKING
©
MODEL ES-1
VIKING
ELECTRONICS
HUDSON, WI 54016
STAND-ALONE
DOOR CONTROLLER
ENTRY SYSTEM
ENTRY POINT
GANG
LOG
PROG
BUS
COMM
PROGRAM
PHONE
or
MODEL ES-1
©
VIKING
ELECTRONICS
HUDSON, WI 54016
STAND-ALONE
DOOR CONTROLLER
ENTRY SYSTEM
ENTRY POINT
WIEGAND
DEVICE
GANG
LOG
PROG
BUS
COMM
1
2
609m (2000 ft) maximum
WIEGAND
DEVICE
Need More Information on the HID-2?
?
Call (715) 386-4345 and select 199.
Viking HID-2
Keypad
(not included)
1219m (4000 ft) maximum
609m (2000 ft) maximum
Viking HID-1
Proximity Card
Reader
(not included)
Need More Information on the HID-1?
?
Call (715) 386-4345 and select 197.
VIKING
MODEL ES-1
©
VIKING
ELECTRONICS
HUDSON, WI 54016
STAND-ALONE
DOOR CONTROLLER
ENTRY SYSTEM
GANG
LOG
PROG
BUS
COMM
PROGRAM
PHONE
1
with 24 gauge wire
and/or
ENTRY POINT
WIEGAND
DEVICE
2

Advertisement