Add Keyless Entry and/or Card Reader Entry
a doorway to control access in both directions (entry and exit). Up to 250 valid Wiegand codes
can be programmed into the ES-1.
Other programmable parameters, like relay activation, mode (normal, off, or open) and facility
codes are also stored in non-volatile memory. All programming is done with a local touch tone
phone. Up to three ES-1s can be programmed simultaneously if they will be sharing all the
same programming codes and parameters. Entry logging is possible with the ES-1's log bus
data output.
P
P
F
e
a
t
u
r
e
s
F
e
a
t
u
r
e
s
• Up to 250 tenants
• Program and control with a Touch Tone phone
• Use with any 26 bit Wiegand device
• Supports 1 entry point
• Compatible with Viking models HID-1 and HID-2
• Non-volatile memory (no batteries required)
• LOG BUS data output for logging entry events
• Card plus keypad mode for highest security
• One time codes for visitors
• Bi-directional (entry and exit) control
i
n
f
o
@
v
i
k
i
n
g
e
l
e
c
t
i
n
f
o
@
v
i
k
i
n
g
e
l
e
c
h
t
t
p
:
/
/
w
w
w
.
v
i
k
i
n
g
h
t
t
p
:
/
/
w
w
w
.
v
i
k
i
n
g
S
S
C
O
M
O
L
U
T
I
O
N
S
C
O
M
O
L
U
T
I
O
N
S
for a Single Door with Up to 250 Users
h
o
n
e
.
.
.
7
1
5
.
3
8
6
h
o
n
e
.
.
.
7
1
5
.
3
8
6
r
o
n
i
c
s
.
c
o
m
t
r
o
n
i
c
s
.
c
o
m
e
l
e
c
t
r
o
n
i
c
s
.
c
o
m
e
l
e
c
t
r
o
n
i
c
s
.
c
o
m
P
r
a
c
P
r
a
2
1
2
1
F
O
R
T
H
E
S
T
F
O
R
T
H
E
S
T
The ES-1 is a door controller designed to operate a
door strike or magnetic lock upon receiving a valid
card read and/or keyless entry code from Wiegand
devices. One ES-1, one or two Wiegand devices and
a door strike or magnetic lock of your choice is
required for each entry point.
The Wiegand device used may be the Viking model
HID-1 Proximity Card Reader and/or the Viking
model HID-2 Wiegand Output Keypad or any other
card reader, RF transmitter or digital keypad that out-
puts the 26 bit Wiegand format. If two Wiegand
devices are used, one can be placed on each side of
A
p
p
A
p
p
.
8
8
6
1
.
8
8
6
1
• Business entrances
• High rise apartment buildings
• Condos
• Senior citizen buildings
• Assisted care centers
• Retirement homes
• Gated communities
S
p
e
c
S
p
e
Power: 120V AC/12V DC 500mA, UL listed adapter provided or
use any 12-24V AC or DC source @ 100mA (designed to share
power with the door strike's power supply)
Dimensions: 133mm x 89mm x 44mm (5.25" x 3.5" x 1.75")
Shipping Weight: 1.3 kg (3 lbs)
Environmental: 0° C to 32° C (32° F to 90° F) with 5% to 95%
non-condensing humidity
Relay Contact Ratings: 5A @ 30V DC/250V AC maximum
Maximum Wiegand Length: 732m (2000 ft) - 24 AWG
Maximum LOG BUS Length: 1610m (5280 ft - 1 mile), 24 AWG
Connections: 11 screw terminals, (1) RJ-11 telco jack
Stand Alone Door
t
i
c
e
c
t
i
c
e
Controller Entry System
C
C
E
N
T
U
R
Y
E
N
T
U
R
Y
l
i
c
a
t
i
o
n
s
l
i
c
a
t
i
o
n
s
i
f
i
c
a
t
i
o
n
s
c
i
f
i
c
a
t
i
o
n
s
ES-1
ES-1
February 15, 2005

Advertisement

loading

Summary of Contents for Viking ES-1

  • Page 1 All programming is done with a local touch tone phone. Up to three ES-1s can be programmed simultaneously if they will be sharing all the same programming codes and parameters. Entry logging is possible with the ES-1’s log bus data output.
  • Page 2 Viking warrants its products to be free from defects in the workmanship or materials, under normal use and service, for a period of one year from the date of purchase from any authorized Viking distributor or 18 months from the...
  • Page 3: Basic Wiring

    * Note: Maximum Wiegand run length is 2000 feet using 24 gauge wire when using the Viking Model HID-1 proxy card reader, and 4000 feet for the HID-2 keypad. Run length is reduced in half if two share the same wire run from the same ES-1 entry point. Run length will also be reduced if using a Wiegand device other than the Viking Model HID-1, that requires more than 35mA average operating current.
  • Page 4: Accessing The Programming Mode

    C. LOG BUS The ES-1 transmits 1200 baud ASCII data from the LOG BUS screw terminals. Log Bus data is sent each time Wiegand data is received from the entry point, and includes: an entry point ID number, if the entry was valid, non-valid, or off, the facility code, and the card number (or keypad entry code).
  • Page 5: Operating Modes

    ES-1 strikes the door when a proper card or keyless code is entered. Enter ✱1 to put the ES-1 in NORMAL mode. Enter ✱0 to put the ES-1 in the OFF mode. In the OFF mode, the ES-1 will not strike the door, even if a proper card or keyless code is entered.
  • Page 6 C. Card Plus Keypad Entry With both a Wiegand card reader and a Wiegand keypad wired to the same ES-1, either can be used to gain access. If the card plus keypad mode is enabled, first the card must match a programmed facility code and entry code, then the same 5-digit entry code must be entered on the keypad for access to be granted.
  • Page 7 Please use these charts to record the numbers programmed into the ES-1 (use pencil). Security Code: Memory Location Tenant’s Name Relay Activation Code: Entry Code # Memory Location Tenant’s Name Entry Code #...
  • Page 8 Tenant’s Name Due to the dynamic nature of the product design, the information contained in this document is subject to change without notice. Viking Electronics, and its affiliates and/or subsidiaries assume no responsibility for errors and omissions contained in this information. Revisions of this document or new editions of it may be issued to incorporate such changes.